726853
16
Zoom out
Zoom in
Previous page
1/42
Next page
16 SPEKTRUM DX18 • TRANSMITTER INSTRUCTION MANUAL
EN
Warnings
The Warnings menu enables you to program a tone or vibration
alert during power on of the transmitter for any selected switch
or channel position.
The alarm activates and an alert message appears on the
screen if a specifi c switch or control stick is in an unsafe posi-
tion when you power the transmitter on.
Return the switch or control stick to the safe position to silence
the alarm.
For safety reasons, the default Throttle alarm activates if the
throttle position is above 10%.
Telemetry
Installing the optional telemetry module and sensors enables the
display of aircraft performance data on the transmitter screen.
You can also enable Data Logging to save a telemetry fi le on
the SD Card and view the data in the Spektrum STi(TM) mobile
application.
Telemetry Settings
Display
Telemetry display options include:
Tele: When you press the scroll wheel, the Telemetry
screens appear and the Main Screen is disabled.
Main: Telemetry alerts appear on the Main screen, but all
Telemetry screens are disabled.
Roller (Default): Allows you to toggle between the Telem-
etry screens and the main screen by pressing the scroll
wheel.
Auto: The Telemetry screen automatically appears as soon
as the transmitter receives data from the telemetry module.
Units
Scroll to Units and press the scroll wheel to change between US
and Metric.
File Settings
This is used to select the data logging settings.
File Name
1. Select File Name to assign a custom fi le name.
2. The File Name screen appears, allowing you to name the fi le
as you would for a Model Name or Flight Mode Name. The
le name can include a maximum of 8 characters.
3. Press BACK to save the name.
Start
1. Select Start to assign a specifi c switch position or stick
position that activates Data Logging.
2. Press the scroll wheel once to save the selection.
Model Reset
Use the Model Reset menu to delete all model programming in
the active model memory. Reset returns all model settings to
the default settings and erases all programming in the selected
model.
After a model reset it is necessary to re-bind.
Model Copy
The Model Copy menu enables you to duplicate model program-
ming from one Model List location to another.
Use Model Copy to:
• Sort the models in the Model List by brand, model type or
power source
• Save a default model copy before experimenting with pro-
gramming values
• Expedite programming for a model using a similar program-
ming setup.
IMPORTANT: Copying a model program from one model
memory to another will erase any programming in the “To”
model memory.
To copy model programming:
1. Make sure the model program you wish to copy is active. If
the desired model program is not active, select Cancel and
change the active model in the Model Select menu.
2. Select the model memory next to “To” and scroll to the
desired model memory. Press the scroll wheel once to save
the selection.
3. Select Copy and the Confi rm Copy screen appears.
4. Select Copy to confi rm. Selecting Cancel will return to the
Model Copy screen.
You cannot use the Model Copy screen to copy model program-
ming to an SD Card. To copy model programming to the SD
Card, please see “Transfer SD Card”.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spektrum DX18 - SPM18000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spektrum DX18 - SPM18000 in the language / languages: English as an attachment in your email.

The manual is 2,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spektrum DX18 - SPM18000

Spektrum DX18 - SPM18000 User Manual - German - 39 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info