Operation of Gate
13
Emergency Release in the Event of a
Power Failure
This procedure should only be applied if the control system is
not powered and is secured against inadvertent activation.
In the event of a power failure, the gate can be manually opened or closed,
irrespective of its initial position.
1. Turn key (6) 90° to the right - emergency release lever is released.
2. Pull emergency release lever (11) from the housing (12); the motor (7) is
removed from the threaded spindle (13).
The springs (36) push the motor (7) from the threaded spindle (13).
To make opening easier: move gate wing manually.
Engaging of drive system
Complete above steps in reverse order.
The emergency release lever (11) must be firmly pressed
against the housing (12).
If the drive is not properly engaged, the motor might be
damaged (7).
Removing the Cover
The cover may only be removed, if the control system is not
powered and is secured against inadvertent activation.