S10564-00001_Rev-A_EN
11. Connections and special functions of the wall
control unit
11.8 Connection options for control
device
IN button and OUT button
External control devices can be connected to the control
unit, for example buttons, pull buttons or key switches.
A separate input is available for the interior and exterior
request sides. The connection is potential-neutral.
IN button
OUT IN
SA
F
OUT
S
A
F
Fig. IN button
If the IN contact is activated, the command of the interior
request side is executed:
Status LED lights up orange during the activation.
Operator opens the door to the door OPEN end
position. Interior: Trafc light off.
Exterior: Red phase.
The door closes automatically after the open
holding and clearing time.
OUT button
OUT IN
SA
F
IN
S
A
F
Fig. OUT button
If the OUT contact is activated, the command of the
exterior request side is executed:
Status LED lights up orange during the activation.
Operator opens the door to the door OPEN end
position.
Interior: Trafc light off.
Exterior: Red phase.
The door closes after the open holding and
clearing time have run out.
11.9 Safety terminal
A potential-neutral NC contact can be connected to this
terminal, for example an emergency stop.
T
X
24
V
GND
IN
SAFETY
PH
O
TX
2
4
V
GND
P
H
O
IN
Fig. SAFETY access
The status LED for the SAFETY lights up green when the
contact is closed.
If the SAFETY safety input is open, the operator
stops during the door movement or no commands are
executed.
Status LED on the control unit ashes.
Resetting the SAFETY safety input
1. Reset safety input
(close contact).
2. Execute a command using the button.
Door opens up to door OPEN end position.
The door closes automatically after the open
holding and clearing time.
65


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer S 9060 Tiga at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer S 9060 Tiga in the language / languages: English as an attachment in your email.

The manual is 28,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer S 9060 Tiga

Sommer S 9060 Tiga User Manual - German - 96 pages

Sommer S 9060 Tiga User Manual - Dutch - 96 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info