680825
63
Zoom out
Zoom in
Previous page
1/96
Next page
63
S10564-00001_Rev-A_EN
11. Connections and special functions of the wall
control unit
11.5 Multi-function relay - MUFU 1
The MUFU 1 multi-function relay can be used for various
functions, such as additional exterior lighting or a door
status display. In delivery condition from the factory, the
multi-function relays outputs a pulse of 1 second every
time the motor starts.
INFORMATION
The functions of the multi-function relay
can be changed by SOMlink, a WLAN-
enabled device and a Memo tiga.
10 additional congurations are available
for the multi-function relay.
Time can also be set for timer operation.
Multi-function relay 1 - MUFU 1
ON
123
MUFU 1
Fig. LED for MUFU 1 Fig. MUFU 1
The status LED for MUFU 1 lights up green when the
relay is energised.
NOTE
Multi-function relay 1 contact is a potential-
neutral changeover contact and may only
be loaded with max. 250 V AC, 5 A or max.
24 V DC, 5 A.
The "Pulse for 1 second when starting motor" function is
set at the factory:
Multi-function relay 1 outputs a pulse of 1 second
every time the motor starts.
11.6 Relay
An additional multi-function relay can be attached at the
Relay slot. Additional functions can be activated, e.g.
exterior lighting or the door status display. The relay is an
optional accessory.
INFORMATION
The functions of the multi-function relay
can be changed by SOMlink, a WLAN-
enabled device and a Memo tiga.
10 additional congurations are available
for the multi-function relay.
Time can also be set for timer operation.
1
4
1
3
3
4
S1
Fig. Relay slot
NOTE
The relay contact is a potential-neutral
changeover contact and may only be
loaded with max. 250 V AC, 5 A or max.
24 V DC, 5 A.
The following function is activated at the factory.
The relay activates for 1 second when the operator
starts.
11.7 Photo eye and frame photo eye
Alternatively a 2-wire photo eye from SOMMER
Antriebs- und Funktechnik GmbH or a 4-wire photo
eye can be connected to the control unit. During
commissioning, the control system automatically detects
which version it is and sets itself to that version.
INFORMATION
If a photo eye is connected for door CLOSE
and detected by the control unit, the
close function is automatically activated.
The position of DIP switch 1 on the carriage
is independent of this.
INFORMATION
If a photo eye is retrotted on a
programmed system, the control
system must be reset, see Chapter
"10.13 Resetting the control unit".
INFORMATION
During commissioning of the photo eye
or the frame photo eye, it must not be
triggered by persons or objects.
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer S 9060 Tiga at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer S 9060 Tiga in the language / languages: English as an attachment in your email.

The manual is 28,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer S 9060 Tiga

Sommer S 9060 Tiga User Manual - German - 96 pages

Sommer S 9060 Tiga User Manual - Dutch - 96 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info