General tips
DIP switch
Depending on the position (OFF or ON) of a DIP switch, a number of
additional functions can be activated or deactivated.
By default, all DIP switches are -> OFF.
Obstacle recognition (DIP 1, 2 + 3)
DIP switch 1
OFF No response in the event of a safety input interruption.
In the event of a force cut-off, the door is halted
ON Drive stops door
(no response at 8.2 kOhm or Fraba system)
DIP switch 2: function - safety connection 1, terminals 6 + 7
OFF NC contact for light barrier / 8.2 kOhm safety contact unit
ON Fraba system
DIP switch 3
OFF Drive stops and opens door a little (reversal).
ON Drive stops and opens door completely.
Safety connection function 1 (DIP 2)
When in position OFF, the drive system automatically detects
whether a light barrier or a 8.2 kOhm bar is connected.
DIP switch 2 (terminal 6 + 7)
OFF Light barrier / 8.2 kOhm safety contact unit
ON Fraba system
Early warning period (DIP 5)
After the button or hand-held transmitter is actuated, the warning light is on
for 3 seconds, before the drive is started and when the drive opens or
closes the door. If the push-button is pressed again or the manual remote
control is operated during the 3 seconds, the early warning period is ended
prematurely.
The early warning period functions in conjunction with both internal lighting
and with a connected warning lamp.
DIP switch 5
OFF Deactivated
ON Activated
Drive behaviour upon closing the door
If the door meets an obstacle (force cut-off) or if the safety input is inter-
rupted (person triggering the light barrier), this is detected by the drive
system, depending on the position of the DIP switches 2 + 3.
Drive behaviour upon opening the door
If the door meets an obstacle (force cut-off) or if the safety input is inter-
rupted (person triggering the light barrier), this is detected by the drive sys-
tem, depending on the position of the DIP switch 1.
Backjump (DIP 6)
In vertical-sectional doors, you have the option of activating
the backjump with DIP switch 6 in order to offload the operator
system and the door. It also facilitates the activation of the
emergency release.
This feature serves the purpose of supporting door and drive mechanism
operation. The drive mechanism moves briefly back in a door OPEN
direction once it has reached the door CLOSED final travel position, thus
taking some of the strain off the other equipment.
DIP switch 6
OFF Deactivated
ON Activated
Defined opening and closing (DIP 7)
Push-button/radio channel 1 open the door and push-button/radio channel
close it. 2-channel operation can also occur using just two push-buttons or
just the manual remote control.
Requirement: DIP switch 8 is OFF; 2 push-buttons are connected or
2 manual remote control push-buttons have been taught in.
DIP switch 7
OFF Deactivated
ON Activated
Partial opening (DIP 8)
This function opens the door either completely or partially, depending on
the given setting.
Ideas for use: garage ventilation, opening of side-opening door for personal
access, to name but a few. Partial opening can also occur using just two
push-buttons or just the manual remote control.
DIP switch 8
OFF Deactivated
ON Activated; DIP switch 7 not functioning
Partial opening using 2 push-buttons
Fit additional push-button and connect as push-button 2 to terminals 4 + 5.
Push-button 1 always opens door fully.
If the door has been partially opened by pressing push-button 2, it can be
fully opened by pressing push-button 1.
Push-button 2 only carries out partial opening when the door is CLOSED.
Should the door have been fully opened using push-button 1 or partially
opened with push-button2,itcanbeclosedbyagain pressing push-button 2.
Procedure:
1. Close door.
2. Set DIP switch 8 to ON, thus activating partial opening functionality
- always leave DIP switch 8 in ON position; the OFF position
automatically deletes the partial opening function that has been set.
3. Press push-button 2 (opens door from CLOSED final travel position)
- door opens until such time as push-button 2 is pressed again or OPEN
final travel position has been reached.
4. Press push-button 2 when the desired position has been reached.
5. Close door by pressing push-button 2.
Partial opening has been memorised and door is opened to set position by
pressing push-button 2.
Set DIP switch 8 to OFF position to delete partial opening setting.
Partial opening via manual remote control
(2-channel operation)
Teaching in 2 manual remote control push-buttons:
e.g. push-button 1 on to radio channel 1 and push-button 2 on to channel 2.
Radio channel l always has the same function as push-button 1;
terminals 2 + 3
Radio channel 2 always has the same function as push-button 2;
terminals 4 + 5.
Procedure as described above.
Functions and Connections marathon
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer Duo 650SL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer Duo 650SL in the language / languages: English as an attachment in your email.

The manual is 4,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer Duo 650SL

Sommer Duo 650SL User Manual - German - 37 pages

Sommer Duo 650SL User Manual - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info