621561
78
Zoom out
Zoom in
Previous page
1/84
Next page
78
v1.06
Admin and Installation Guide M700, M300 Description of Settings
Setting Description
DECT system settings
RFPI system The RFPI of the base station is entered automatically.
Auto congure DECT sync
source tree
Allows the multicell system to automatically synchronize the multicell chain/
tree. This setting must be enabled to allow a secondary base station to take
over the primary base station function if the original base station becomes
disabled.
Default: Enabled
Allow multi primary This feature allows two or more primaries in the same system and is used for
multilocation setups. The primaries are unsynchronized, and handover is not
possible. The setting Auto congure DECT sync source tree must be enabled.
Default: Disabled
Auto create multi primary Available when the setting Allow multi primary is enabled. This setting
enables the multicell system to generate a second cell when a base station
goes o-line and radio connection between parts of the system is lost. After
reconnecting the faulty base station, the system must be rebooted.
Default: Disabled
Base station settings
Number of SIP accounts
before distribution load
The maximum number of handsets that are permitted to perform location
registration on a specic base station before the load is distributed to other
base stations. The parameter can be used to optimize handset distribution
among visible base stations.
Note: In a multi-cell setup, a maximum of 8 simultaneous
calls can be routed through each base station.
Permitted input: Positive integers (e.g., 8)
SIP server support for
multiple registrations per
account
Select option from drop-down menu.
Disabled: (For servers that do not support moving SIP registrations from
base station to base station when handset roams.) The SIP registration of
a handset remains on the original base station when the handset roams to
another base station. The handset does not SIP-register on the second base
station.
Enabled: When a handset roams to another base station, the SIP registration
of the handset on the original base station is deregistered, and the handset
SIP-registers on the second base station.
Default: Disabled
System combination (number
of base stations/repeaters
per base station)
Three settings are available.
Note: The conguration must be set at the time the multicell
system is congurated. It cannot be modied:
50/3: 50 base stations and 3 repeaters
127/1: 127 base stations and 1 repeater
254/0: 254 base stations and 0 repeater
Base Station Group
ID Base station identity in the chained network. Automatically assigned
consecutively when new base stations are added to the chain. With checkbox
for selection for removal from chain.
Permitted output: Positive integers.
RPN The Radio Fixed Part Number is an 8-bit DECT cell identity allocated by the
installer. The allocated RPN within the SME must be geographically unique.
Permitted output: 0 to 255 (DEC) or 0x00 to 0xFF (HEX)
Version Current rmware version on base station.
Permitted output: Positive integers with dot (e.g, 355.21).
78


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Snom M300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Snom M300 in the language / languages: English as an attachment in your email.

The manual is 2.57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Snom M300

Snom M300 User Manual - English - 44 pages

Snom M300 User Manual - English - 38 pages

Snom M300 User Manual - English - 58 pages

Snom M300 User Manual - German - 82 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info