621561
77
Zoom out
Zoom in
Previous page
1/84
Next page
77
v1.06
Admin and Installation Guide M700, M300 Description of Settings
Multicell
Please note that all base stations in a multicell setup must have the same rmware. We recommend
that you update all base stations to the latest rmware and reset them before beginning the multicell
installation.
Reset secondary base stations to defaults, and, after the reset, change their DHCP Options
"Plug-n-Play" setting on the Network page to "Disabled".
Use only the designated primary (master) base station to enter all data, i.e., set up the SIP
server(s), creating extensions/user accounts, register handsets, etc.
Note: Entering a time server on the Time settings page of the primary base station's web
interface is mandatory for multicell installations!
Setting Description
Settings for this unit
Multicell system Select "Enabled" or "Disabled" from the drop-down list.
Default: Disabled.
System chain ID All base stations in a multicell system must have the same system chain ID.
Note 1: The chain ID is used as a SIP account, i.e., extension 512, to
identify dierent DECT chains in the same network. This means that you
cannot assign extension 512 to handsets or use it for calls. It is possible
to assign a dierent chain ID, but by provisioning only (valid input: up to
5 digits).
Note 2: There can be several multi-cell systems in the network. Up to 24
levels of base station chains are permitted.
Default: 512
Synchronization time (s) Species the period in seconds when base stations in a multicell system
synchronize with each other. If no keepalive packets are received within this
period, the base station will be treated as unreachable in the multicell system.
Default: 60 seconds
Data Sync Select multicast or peer-to-peer from the drop-down menu. Multicast
uses UDP. The multicast port (range 49200-49999) and IP address (range
224.1.0.0-225.1.0.0) are calculated from the chain ID.
Default: Multicast
Primary data sync IP IP address of base station data sync sourse, i.e., the base station handling the
data synchronization.
When the data sync setting is multicast, this setting is disabled; the IP is
selected automatically.
If data sync setting is peer-to-peer, the source must be dened. The
default value is 0.0.0.0.
Multicell debug 224.1.0.0-225.1.0.0)
None: Debug disabled.
Data sync: Writes header information for all packets received and sent,
to be used to debug any special issues.
Note: This option should only be enabled for short periods of
time when debugging is needed, as it generates a lot of syslog
signaling.
Auto tree: Writes states and data related to the auto tree conguration.
Both: "Data sync" and "auto tree" are both enabled.
Note: This option must only be used for debugging and not
enabled on a normal running system.
Default: None
77


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Snom M300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Snom M300 in the language / languages: English as an attachment in your email.

The manual is 2.57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Snom M300

Snom M300 User Manual - English - 44 pages

Snom M300 User Manual - English - 38 pages

Snom M300 User Manual - English - 58 pages

Snom M300 User Manual - German - 82 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info