28530
41
Zoom out
Zoom in
Previous page
1/182
Next page
Operational procedures
33
850-164692 / Rev.B
The polynomial model is a flexible function capable of
modelling complex function shapes. The polynomial model is
onlyusedtocheckinthePlot view that the estimated
polynomial model has the same shape as the shape of the beam
model. If the shape of the polynomial model is very different
from the shape of the beam model, this indicates that either
insufficient data have been collected, or some data points may
be associated with errors (broken cables or channel wires
mixed).
The beam model is the model actually used by the echo sounder.
The calibration program will adjust the parameters in the beam
model to minimise the RMS-error calculated on the recorded
data points. The adjusted parameters, the RMS-error, and the
data points having maximum and minimum deviation from the
model are shown in the Information view. The adjusted
parameters resulting from the beam model are the parameters,
which can be transferred to the echo sounder and used for the
transducer during operation. Information on data deviation from
the beam model will indicate how well the beam model fit the
recorded data. This can be used to evaluate the validity of the
recorded data points.
The data evaluation should start using the Plot view and the
polynomial model to check the shape of the polar plot. A
circular transducer should have a circular beam and an elliptic
transducer an ellipse, both with only insignificant offset angles.
If a circular transducer in the Plot view shows an ellipse with
approximately 45 or 135 degrees axis, the reason may be one
missing quadrant in the transducer or one missing quadrant in
the receiver. This symptom should also give approximately 2 dB
lower TS, i.e. 1dB lower transducer gain to compensate.
If a circular transducer in the Plot view shows an non circular
shape, and in addition substantial offset angles both athwart and
alongship, this indicates there may be something wrong in the
way the transducer is connected. In this case, you must select
the View menu and check the calibrated beamwidth, offset and
gain values. If one quadrant of the transducer is inversely
connected, the beamwidth will be approximately one degree too
wide, the offset angles will be approximately one degree off
centre in both directions and the calibrated gain can be in the
order of 6 dB lower than the default gain.
If two of the quadrants have been mixed up, the reference
sphere’s movements inside the beam will be incorrect. This can
be confirmed when the reference sphere is suspended in such a
way that you can move it in a specific direction. This direction
is either transversal or longitudinal in the transducer beam.
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad ER60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad ER60 in the language / languages: English as an attachment in your email.

The manual is 3,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info