Specifications
DH12400M DH18400M DH21400M DH24400M DH40018M DH40021M DH40024M
Rated power [kW]
13.2 18 21 24 18 21 24
Rated voltage
400 V 3~ 400 V 3~ 400 V 3~ 400 V 3~ 400 V 3~ 400 V 3~ 400 V 3~
Economy setting e [kW]
1st stage ––––678
2nd stage 8 12 14 16 12 14 16
Intensive setting II [kW]
1st stage ––––910.5 12
2nd stage 12 18 21 24 18 21 24
Switch-on point [I/min]
1st stage ––––4.04.55.0
2nd stage 3.6 5.0 5.8 6.6 5.0 5.8 6.6
Mixed water [I/min] at rated power
approx. 38 °C 6.6 9.9 11.6 13.2 9.9 11.6 13.2
approx. 50 °C
(supply temperature 12 °C)
4.5 6.8 7.9 9.1 6.8 7.9 9.1
Minimum flow pressure of appliance*
[MPa (bar)]
with flow limiter 0.03 (0.3) 0.07 (0.7) 0.08 (0.8) 0.09 (0.9) 0.07 (0.7) 0.08 (0.8) 0.09 (0.9)
without flow limiter 0.02 (0.2) 0.04 (0.4) 0.05 (0.5) 0.06 (0.6) 0.04 (0.4) 0.05 (0.5) 0.06 (0.6)
Application area in water specific
electric resistance at 15 °C [Ωcm]
≥ 800 ≥ 1 300 ≥ 1 300 ≥ 1 300 ≥ 1 300 ≥ 1 300 ≥ 1 300
Rated pressure [MPa (bar)]
1 (10) 1 (10) 1 (10) 1 (10) 1 (10) 1 (10) 1 (10)
Maximum permissible
supply temperature [°C]
20 20 20 20 20 20 20
Energy efficiency class
AAAAAAA
Load profile
SSSSSSS
Annual energy consumption [kWh]
480 481 483 483 481 483 483
Daily energy consumption [kWh]
2.213 2.215 2.228 2.232 2.215 2.228 2.232
Sound power level [dB]
15 15 15 15 15 15 15
Hot water heating energy efficiency [%]
38.4 38.4 38.2 38.1 38.4 38.2 38.1
* Plus any pressure loss at the tap mixer
C
Dimensions
Special accessories
BZ45U21 Pipe set: for use of the continuous-flow heater
as an under sink appliance
Priority switch (load shedding relay) BZ45L21:
for operation with the priority circuit
Mounting set BZ45K23: for surface-mount installation
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens DH40018M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens DH40018M in the language / languages: English, German, Dutch, French, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 4,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info