47
-
indicator on button “A”.
If all appliances are heated up, the boiler switches to ‘reduce’ - see chap. 6.2. It is indicated with
the mode “External OFF” on the display and with the blinking green light of the indicator on button
“A”.
If a demand for heating from any appliance is received, the furnace is blown by the fan and the
normal operation of the boiler continues. It is indicated with the mode “Operation on the display
and with the green light of the indicator on button “A”.
When the boiler switches to the mode ‘normal operation’, the furnace begins to burn again. If the
furnace burns insufficiently even if the time set in Delay time of ignition after reduce (see chap.
6.2.1.) has already passed, the automatic ignition is put into operation.
7.1.6. FLUE DAMPER CONFIGURATION
The selection Flue damper (YES/NO) defines whether the boiler is equipped with the flue damper,
which is automatically controlled according to the flue gas temperature in the chimney, or not.
This additional attachment is currently being developed and it is not a part of the existing boilers.
The default value is NO. The instructions for changing this parameter can be found in chapter 4.
7.1.7. INFLUENCE OF APPLIANCE ON RETURN TEMPERATURE CONFIGURATION
The selection Influence of appliance on return temperature (YES/NO) is a special way to
protect the return valve of the boiler against the low-temperature corrosion.
The selection Influence of appliance on return temperature YES is used if the boiler is
installed into the heating system according to the instructions described in chap. 11.3. It means
that the primary circuit of the boiler does not include the mixing valve Y7 that would control the
return valve temperature but the temperature is controlled by switching the individual appliances
(heating circuits, DHW storage tank).
This setting cannot be used if the boiler has a buffer storage tank or if more boilers are connected
in a cascade!
The selection Influence of appliance on return temperature – NO is used if the boiler is
protected against low-temperature corrosion by the mixing valve Y7 in the primary circuit of the
boiler– see instructions in chap. 11.1., 11.2., or 11.4.
The default value is NO. The instructions for changing this parameter can be found in chapter 4.
7.1.8. BUFFER CONFIGURATION
The selection Buffer (YES/NO) defines whether the heating system is equipped with a buffer
storage tank or not.
The setting Cascade boiler 2, boiler 3, boiler 4 is incompatible with the configuration setting
Buffer (see chap. 7.1.).
The default value is NO. The instructions for changing this parameter can be found in chapter 4.
47


Need help? Post your question in this forum.

Forumrules
1

Forum

siemens-climatix-2

Reset search

  • salve
    chiedo se è possibile fare un by pass per far partire il sistema di condizionamento a causa dell'oscuramento :del controllore POL/STD
    grazie
    Submitted on 11-3-2022 at 12:44

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens Climatix 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens Climatix 2 in the language / languages: English as an attachment in your email.

The manual is 1,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info