INSTRUCTION MANUAL OF THE SIEMENS CLIMATIX 2 CONTROL EQUIPMENT
-
45
-
External input Yes / No
Substitute operation Yes / No
B9 outside sensor Auto / Not used
After selecting the configuration of the boiler and the heating system, it is necessary to confirm this
selection by Save configuration.
If the operator does not make any other selections within 30 s. after making the last selection, the
configuration is saved automatically. The remaining time until the configuration is saved
automatically is indicated on the last line Autosave in: … s.
If the selected configuration is saved, the control equipment is restarted and only the newly
selected equipment of the boiler and the heating system (including specific functions) is loaded.
Everything else remains hidden and does not affect the boiler operation.
If the selected configuration is incompatible with some functions, the control equipment is restarted
once again and the incompatible settings are cancelled, e.g. the function ‘buffer cannot be
selected for the boilers 2, 3, 4 in the cascade.
7.1.1. CASCADE CONFIGURATION
The selection Cascade (OFF / Boiler 1 Master / Boiler 2 / Boiler 3 / Boiler 4) defines the number of
boilers in the heating system that are connected to a cascade.
If there is only one boiler in the heating system, it is necessary to select OFF.
In the case of a cascade, it is necessary to select Boiler 1 “Master” for the first boiler in the
cascade, Boiler 2 for the second boiler, Boiler 3 for the third boiler, and Boiler 4 for the fourth
boiler.
In the case of a cascade, the heating system must include a hydraulic equalizer of dynamic
pressures (HEDP - torus) or a buffer tank with a sensor B10 installed at the outlet into the heating
system. The sensor B10 is installed in the control equipment of boiler 1 “Master” instead of the
sensor B3 DHW.
The default value is OFF. The instructions for changing this parameter can be found in chapter 4.
7.1.2. SMS SERVER CONFIGURATION
The selection SMS server (YES/NO) enables to send certain information about the boiler
operation to a mobile phone.
This additional attachment is currently being developed and it is not a part of the existing boilers.
The default value is NO. The instructions for changing this parameter can be found in chapter 4.
7.1.3. OXYGEN SENSOR CONFIGURATION
The selection Oxygen sensor (YES/NO) defines whether the boiler is equipped with this sensor or
not.
The default value is NO. The instructions for changing this parameter can be found in chapter 4.
Version 3 is a former version of the oxygen sensor and it stopped being used in 2013. Currently,
version 4 of the oxygen sensor is used.
45


Need help? Post your question in this forum.

Forumrules
1

Forum

siemens-climatix-2

Reset search

  • salve
    chiedo se è possibile fare un by pass per far partire il sistema di condizionamento a causa dell'oscuramento :del controllore POL/STD
    grazie
    Submitted on 11-3-2022 at 12:44

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens Climatix 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens Climatix 2 in the language / languages: English as an attachment in your email.

The manual is 1,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info