The selection Idle is the reversed operating logic; i.e. if the contact of the room thermostat is
opened, the heating is switched to the “frost protection” mode. This selection is more common in
practice. It is set when the standard room thermostat (e.g. SIEMENS REV24DC or cordless
SIEMENS REV24RFDC/SET) is used and when closing the contact means “heating”.
If HC1 is not configured and the heating system should be controlled by the room thermostat, it is
necessary to set External input - YES in the configuration (see chap. 7.1.) and to connect the
room thermostat with the External input pins (see chap.5.10.).
6.5. HEATING CIRCUIT 2
The heating circuit 2 control is analogous to the heating circuit 1 control – see chap. 6.4.
Only the identification marks are different:
Mixing valve HC2 is marked as Y5 (not Y1)
Pump HC2 is marked as Q6 (not Q2)
Flow temperature HC2 sensor is marked as B12 (not B1)
Room temperature HC2 sensor is marked as A7 (not A6)
Room thermostat HC2 is marked as H3 (not H1)
6.6. STATE OF BINARY INPUTS
The user can comprehensively check the operating states of all the binary inputs at the moment.
It includes these appliances:
External input ON/OFF
Safety thermostat OK/Error
Backfire sensor OK/ Error
Boiler hopper lid OK/ Error
Room thermostat H1 HC1 Active/Passive
Room thermostat H3 HC2 Active/Passive
6.7. STATE OF BINARY OUTPUTS
The user can comprehensively check the operating states of all the binary outputs at the moment.
It includes these appliances:
Feeder 1 ON/OFF
Feeder 2 ON/OFF
Deasher ON/OFF
Ignition ON/OFF
Flue gas outlet ON/OFF
Boiler pump ON/OFF
Pump HC1 ON/OFF
39


Need help? Post your question in this forum.

Forumrules
1

Forum

siemens-climatix-2

Reset search

  • salve
    chiedo se è possibile fare un by pass per far partire il sistema di condizionamento a causa dell'oscuramento :del controllore POL/STD
    grazie
    Submitted on 11-3-2022 at 12:44

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens Climatix 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens Climatix 2 in the language / languages: English as an attachment in your email.

The manual is 1,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info