Installation instructions for trained electricians only
5 Variant 2
Installing humidity/temperature
sensorFTS II Fig. 6 7
Install the humidity/temperature sensor FTS II in the
sauna cabin about 15 cm below the ceiling and oppo-
site of the heating system.
Connect the humidity/temperature sensor FTS II only
with the supplied 150° C temperature-resistant con-
necting line or an equivalent temperature-resistant line.
On the outside of the sauna cabin, the temperature-
resistant connecting line can be extended with custo-
mary lines.
WARNING - Electric shock:
Run the power cables separate to other sen-
sor and control lines.
Protect single insulated lines with a pipe
(double insulation).
1. Run the line to the mounting location of the humi-
dity/temperature sensor FTS II 2 in the cabin wall
and fix in position with wiring clips.
2. Connect terminals of up to 150° C temperature-
resistant line to sensor terminals 3 according to
circuit diagram 7.
3. Conduct tests according to the chapter “Tests”.
4. Fix humidity/temperature sensor FTS II 2 to the
cabin wall opposite of the heating system with two
wood screws 1 keeping a distance of 15 cm to
the ceiling.
6 Tests
An authorized electrician must carry out the tests.
WARNING - Electric shock:
The following tests are carried out with the
supply voltage switched on.
1. Check the contacts of the ground terminals.
2. Test the safety shutdown with the line to the tem-
perature sensor F I interrupted.
- The lines have to be disconnected at the sensors
to include the stove sensor lines in the test.
- The heating system has to shut down on its own
when the white or red stove sensor lines are dis-
connected and in case of a short circuit in the white
line.
3. Test the phase interconnection for sauna opera-
tion L1, L2, L3 to U, V, W.
4. Test the phase interconnection for climate opera-
tion L1, L2, L3 to U, V1, W.
5. Test for maximum permissible heat output of CK
3 sauna control of 3.5 kW per phase.
6. With connected, optional additional power unit:
- Check control lines St1, St2 and St3,
- Test for maximum permissible heat output of op-
tional power unit S2-18 of 3 kW per phase.
- Test for maximum permissible heat output of op-
tional power unit S2-30 of 7 kW per phase.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sentiotec CK 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sentiotec CK 3 in the language / languages: English, German as an attachment in your email.

The manual is 0,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info