735538
5
Zoom out
Zoom in
Previous page
1/14
Next page
Jumper
Position
Function
Start point
selection
jumper
0%
20%
Jumper top position provides 0Vdc or 0mA start point for Out(1), Out(2)
(0-20mA or 0-10V).
Jumper bottom position provides 2Vdc or 4mA start point for Out(1), Out(2)
(4-20mA or 2-10V).
Communi-
cation
selection
jumper
MB
SA
Modbus communication protocol
Senseair communication protocol
Out(1)
Current
Voltage
Connection in position “Current” provides 0/4-20mA output range for Out(1).
Connection in position “Voltage” provides 0/2-10VDC output range for
Out(1).
Out(2)
Current
Voltage
Connection in position “Current” provides 0/4-20mA output range for Out(2).
Connection in position “Voltage” provides 0/2-10VDC output range for
Out(2).
Out(4)
Voltage
Open
collector
Connection in position “Voltage” provides 0-10VDC for Out(4).
Connection in position “Open collector” provides an open collector output.
Max 0.5A, 55VDC / 40VAC (half-wave rectifier).
Table II. Configuration jumpers for aSENSE mIII
Option - Network Adapter for Connection to RS-485-Network
The network adapter can be used to connect the Senseair sensor to a RS-485-network. The adapter
is a small printed circuit board which can be used with all sensors with the housings large enough. The
green LED flashes every time the adapter answers calls from the network master.
The adapter should be mounted perpendicular to the main PCB. The adapter should be put on the
UART connector with all five pins connected. All five pins of the UART must be connected. For
aSENSE the adapter should be mounted with the RS-485 terminal facing the other terminals and the
LED facing the display.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Senseair aSENSE M III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Senseair aSENSE M III in the language / languages: English as an attachment in your email.

The manual is 1,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Senseair aSENSE M III

Senseair aSENSE M III Installation Guide - English - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info