A label on the inner side of the sensor lid shows the configuration of the outputs at the time of product
delivery. The sensors/controllers are supplied from the factory (unless otherwise ordered) with
0...10VDC linear outputs for Out(1) and Out(2). Out(4) is an open collector output (see Table II). If
different output configurations are needed for the application, these have to be reconfigured before the
unit is powered up. Default values are 0-10 V.
Figure 5 The connection terminal area of the aSENSE mIII with jumpers and terminals. The terminal
DI1 may be used for forced ventilation. If the sensor has a heater it is connected to and .
DI1
~
+
~
+
DI1 Switch
for alarm
test
Jumpers to
choose
between
voltage or
current
outputs
Jumper to choose
between open
collector or 0-10V
linear signal
Jumper to
choose
communication
protocol
Jumper for
configuring the
linear output
start point to 0%
or 20% start
point
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Senseair aSENSE M III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Senseair aSENSE M III in the language / languages: English as an attachment in your email.

The manual is 1,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Senseair aSENSE M III

Senseair aSENSE M III Installation Guide - English - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info