64 VERSA IP SATEL
Tamper signaling is blocked:
when the control panel is running in service mode,
when the ABAX system is running in test mode (ASP-105 and ASP-205),
for 10 minutes after connecting the battery (ASP-100),
for 40 seconds after power-on (ASP-105) / installing the battery (ASP-205).
It enables installation work to be carried out. Opening the tamper switch will not trigger
loud signaling, but information on tamper will be sent (when in service mode, the
control panel will not signal the tamper alarms). The command to block/unblock the
signaling connected with starting / ending the test mode or the service mode is sent
during the response time.
Wireless expanders of hardwired zones and outputs
The wireless expander of hardwired zones and outputs (ACX-200 or ACX-201) takes up 4
zones and 4 outputs in the system. The alarm system zone / output to which the zone /
output in ACX-200 or ACX-201 expander is assigned is programmed in the same way as the
other hardwired zones / outputs of the control panel. You should remember however that
sensitivity of the expander zones may be different from that programmed in the control panel:
from 20 ms to 140 ms – the same as the value programmed in the control panel,
above 140 ms – only some values are available: 300 ms, 500 ms, 700 ms, etc. every
200 ms (the programmed value is rounded up to that supported by the expander).
The EN50131-3 standard requires that zones must react to signals lasting more than
400 ms. It means in case of the wireless expanders of hardwired zones and outputs
that no values exceeding 300 ms should be entered when programming the sensitivity
(the higher the value, the lower the sensitivity).
The expander informs you about the zone status as it changes. Also the expander outputs
are controlled in real time. Only the programming of zones takes place during the response
time (in one period, data relating to configuration of one zone are sent to the expander
module, i.e. sending the information on settings of four zones require four response periods).
If communication with the controller is lost, all previously activated outputs will be
deactivated after 20 response periods.
Additionally, the ACX-201 expander module sends information about:
status of AUX1 and AUX2 power supply outputs – information on overload is sent when
the AUX1 or AUX2 output load exceeds 0.5 A.
battery status – information on low battery is sent when the battery voltage drops below
11 V for more than 12 minutes (3 battery tests). The expander will kept sending this
information to the controller until the battery voltage rises and remains above 11 V for
longer than 12 minutes (3 battery tests).
AC power status – information on the loss of power supply is sent when the AC power loss
lasts for more than 30 seconds. The AC power restore is reported with the same delay.
Low battery information for the first zone of ACX-201 expander indicates overload of the
AUX1 or AUX2 power supply output, for the second zone – discharged battery, for the third
zone – loss of AC power.
230 V AC wireless controllers
Activation of the output to which the controller is assigned will result in energizing the
230 V AC electrical circuit (if reverse polarity of the output has been programmed, the circuit
will be deenergized).
66


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Versa IP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Versa IP in the language / languages: English as an attachment in your email.

The manual is 1,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Versa IP

Satel Versa IP Quick start guide - English - 11 pages

Satel Versa IP User Manual - English - 32 pages

Satel Versa IP Installation Guide - English - 36 pages

Satel Versa IP User Manual - English - 43 pages

Satel Versa IP Quick start guide - German - 11 pages

Satel Versa IP Additional guide - German - 97 pages

Satel Versa IP User Manual - German - 45 pages

Satel Versa IP Installation Guide - German - 38 pages

Satel Versa IP Quick start guide - Dutch - 2 pages

Satel Versa IP User Manual - Dutch - 45 pages

Satel Versa IP Quick start guide - Dutch - 12 pages

Satel Versa IP Additional guide - Dutch - 93 pages

Satel Versa IP User Manual - Dutch - 45 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info