629722
91
Zoom out
Zoom in
Previous page
1/93
Next page
SATEL VERSA IP 89
identifier of INT-VG module (assigned by the VG-SOFT program),
identifier of the data file (assigned by the VG-S
OFT program).
14.2 Running the VG-Soft program for the first time
1. Connect the USB port of control panel to the computer port.
2. Start the VG-SOFT program using the button available in the DLOADX program (“VERSA
– Structure” window “Hardware” tab “INT-VG module”). Connection of the DLOADX
program with the control panel will be automatically interrupted.
Do not resume the connection between DLOADX program and control panel as long
as you are configuring the voice module by means of the VG-SOFT program.
3. When a window is displayed with a prompt whether to connect to the voice module, click
“Yes”.
4. When a window is displayed with a prompt whether to read the module data, click “Yes”.
The program will read data from the module.
5. If you want to use the user messages in the voice menu, configure respectively the
messages from “Names” group (you can copy the names from the control panel in the
“Names: INT-VG / Control panel” tab).
6. If the control panel is to notify of events by means of voice messages, enter the content of
notification messages (You can copy the content of notification messages from the control
panel in the “Names: INT-VG / Control panel” tab).
7. In the “Messages” tab, select the software voice synthesizer you want to be used for
synthesizing the messages, and then click on “Synthesize all”.
8. If macro commands are to be available in the voice menu, configure them in the “Macros”
tab.
9. Click on the button to write data to the voice module.
14.3 Restoring the voice module default settings
In order to reset the voice module to its factory default settings, click “Configuration”
“Factory default settings” in the VG-S
OFT program.
15. Compliance with EN 50131 standard requirements for Grade 2
To meet the requirements of EN 50131 standard for Grade 2, do the following:
enable the global options:
– GRADE 2,
– TROUBLE MEMORY UNTIL REVIEW,
– EVENTS AMOUNT LIMITING (in the DLOADX program, the option is available in the
reporting options),
– BLOCK AFTER 3 UNKNOWN CODES/CARDS.
disable the global options:
– TAMPER ALARM ALWAYS AUDIBLE,
– ARM EVEN IF NOT READY AFTER EXIT DELAY.
program the AC loss time after which a trouble will be reported to be no longer than 60
minutes (AC LOSS REPORT DELAY global parameter),
91


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Versa IP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Versa IP in the language / languages: English as an attachment in your email.

The manual is 1,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Versa IP

Satel Versa IP Quick start guide - English - 11 pages

Satel Versa IP User Manual - English - 32 pages

Satel Versa IP Installation Guide - English - 36 pages

Satel Versa IP User Manual - English - 43 pages

Satel Versa IP Quick start guide - German - 11 pages

Satel Versa IP Additional guide - German - 97 pages

Satel Versa IP User Manual - German - 45 pages

Satel Versa IP Installation Guide - German - 38 pages

Satel Versa IP Quick start guide - Dutch - 2 pages

Satel Versa IP User Manual - Dutch - 45 pages

Satel Versa IP Quick start guide - Dutch - 12 pages

Satel Versa IP Additional guide - Dutch - 93 pages

Satel Versa IP User Manual - Dutch - 45 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info