SATEL INT-TSG 17
8. If the macro command is not to be available, when any of the partitions operated by the
keypad is armed, enable the D
ISABLED IF ARMED
option.
9. If the macro command is to be run instantly on tapping the icon of macro command group,
enable the A
UTOEXECUTE
option (if so, only this single macro command is to be assigned
to the group).
10. If the confirmation messages are not to be displayed after running the macro command,
enable the N
O CONFIRMATION MESSAGES
option.
11. Select the icon which will be used to present the macro command on the keypad.
12. If the icon is to present the status of selected output:
enable the S
TATE FOLLOW OUTPUT
option;
indicate the output number;
select the icons which will illustrate inactive and active status of the output.
13. Click on the button in the “Command” field and select from the list the function the new
macro command is to execute.
14. Program the command parameters as required.
15. Click the “Add” button. A new command will appear in the list of commands assigned to
the macro command. After clicking the command you can still make a correction of its
parameters. After making the changes, click the “Change” button.
16. Repeat the steps 13-15, if you want to add next commands.
17. Click the “Groups” tab.
18. Click the group to be edited.
19. Enter the group name, if it is to be displayed on the keypad.
20. Select the icon which will be used to present the group of macro commands on the
keypad.
21. Enable the M
ACRO AVAILABLE ON THE STATUS SCREEN
option for the group, if macro
commands assigned to the group are to be displayed after touching a corner of the status
screen.
22. Enable the I
CON VISIBLE ON THE STATUS SCREEN
option for the group, if the group icon is to
be displayed in a corner of the status screen.
23. Click the “Add macro” button. A list of all defined macro commands will be displayed.
24. Click on a macro command to add it to the group. The macro command will be put in the
tree under the group.
25. Click on the “Write” button to write the macro command related data to the keypad.
7.1.5 Status screen
The status screen related data are stored in the keypad memory. Before you start
configuring the status screen, click on the “Read” button in the “Status screen” tab to
read the data from the keypad. Having configured the status screen, click on the
“Write” button in the “Status screen” tab to write the data to the keypad. The status
screen related data are not read / written when you click on the button in the
main menu of D
LOAD
X program.
If the I
CON VISIBLE ON THE STATUS SCREEN
option is enabled for a group of macro
commands, do not place any elements in the screen corner where the icon will be
displayed, or they will be covered by the icon. The D
LOAD
X program indicates using
appropriate graphic symbols the screen corners where the icons will be displayed.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel INT-TSG-BSB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel INT-TSG-BSB in the language / languages: English as an attachment in your email.

The manual is 0,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel INT-TSG-BSB

Satel INT-TSG-BSB Quick start guide - English - 2 pages

Satel INT-TSG-BSB User Manual - English - 20 pages

Satel INT-TSG-BSB User Manual - English - 18 pages

Satel INT-TSG-BSB Quick start guide - German - 2 pages

Satel INT-TSG-BSB User Manual - German - 19 pages

Satel INT-TSG-BSB Installation Guide - German - 29 pages

Satel INT-TSG-BSB Quick start guide - Dutch - 2 pages

Satel INT-TSG-BSB User Manual - Dutch - 18 pages

Satel INT-TSG-BSB User Manual - Dutch - 20 pages

Satel INT-TSG-BSB Installation Guide - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info