EXAMPLE:
LEDs: 1,3,6,8 are on, which gives value = 165:
State of the LEDs from 1 to 8 :  
VALUE
: 128+32 + 4+1 = 165
REACTION TIME
(ms):
PROGRAMMED VALUE
(165)
X
16
ms
=
2640
ms
FS25 - programming zone type (DEC)
Selection of the zone type depends on the detector type and configuration of connection to
the control panel. The following types of detectors and configurations are possible: NC,
NO, EOL, 2EOL/NC, 2EOL/NO. Determination of the configuration and the detector type is
necessary, since control panel interpretation of received information will depend on it. For
example, an open zone can mean correct state of the NO detector or violation of the NC
detector, as well as tamper in case of 2EOL configuration.
Programming consists in entering the suitable two-digit number (to determine the zone
type) for the particular zones. Having confirmed the detector type for one zone, the control
panel proceeds to programming the next zone type, until zone types are assigned to all 16
zones. The following numbers are correct:
00 - no detector (for unused zones)
01 - NC (normally closed)
02 - NO (normally open)
03 - EOL (end of line resistor –by default)
04 - 2EOL/NC (double end of line resistor – NC type detector)
05 - 2EOL/NO (double end of line resistor – NO type detector)
During the programming, the control panel displays the current parameter setting (in binary
format) on LEDs 1 to 8. The AB, AB LEDs show the zone for which the detector type is
being programmed.
EXAMPLE:
programming the EOL zones type for 1 - 6 zones, NC type for 7 - 8 zones,
[12345] [#] - enter the service mode
[2][5] [#] - call the function
[0][3] [#] - detector type for the first zone (AB, AB = 0001)
[0][3] [#] - detector type for the second zone (AB, AB = 0010)
[0][3] [#] - detector type for the third zone (AB, AB = 0011)
[0][3] [#] - detector type for the fourth zone (AB, AB = 0100)
[0][3] [#] - detector type for the fifth zone (AB, AB = 0101)
[0][3] [#] - detector type for the sixth zone (AB, AB = 0110)
[0][1] [#] - detector type for the seventh zone (AB, AB = 0111)
[0][1] [#] - detector type for the eighth zone (AB, AB = 1000)
the control panel automatically exits the function
FS26 - programming zone reaction type (zone function) (DEC)
The control panel reaction to a zone violation depends on the function assigned to the
given zone (e.g., the reaction will be different in case of a “24 h fire” type zone violation,
and in case of an “arming” zone violation).
The programming consists in entering an appropriate two-digit number for each zone to
determine its function (reaction type). Each of the CA-6 zones can perform one of the 20
functions:
00 - ENTRY/EXIT
01 - DELAYED
02 - INTERIOR DELAYED
03 - INSTANT
04 - DAY/NIGHT
05 - COUNTING C1
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-6 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-6 in the language / languages: English as an attachment in your email.

The manual is 0,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-6

Satel CA-6 Quick start guide - English - 8 pages

Satel CA-6 Installation Guide - English - 36 pages

Satel CA-6 Additional guide - German - 19 pages

Satel CA-6 User Manual - German - 19 pages

Satel CA-6 Installation Guide - German - 80 pages

Satel CA-6 User Manual - German - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info