Prog.
No.
Reasonable areas of application
Indications
Possible electrode
position
Phase Running time
( minutes)
21 Shaping of upper limbs
12 – 17
120
220
22 Increasing size of upper limbs
12 – 17
115
23 Toning of hips and thighs
20, 23, 24
120
210
24 Strengthening of hips and thighs
20, 23, 24
120
210
25 Toning of gluteal muscles
22
120
210
26 Strengthening of gluteal muscles
22
120
210
27 Shaping of gluteal muscles
22
120
220
The EMS 28 30 programme can be set individually, see 7.3.3 (p. 24).
6.5 MASSAGE program table
Prog.
No.
Reasonable areas of application
Indications
Phase Running time
( minutes)
1 Muscle strain relief 1 20
2 Relaxing massage 1 25
3 Invigorating massage 1 20
4 Tapping massage 1 15
5 Tapping and jet massage 1 15
6 Vibrating massage 1 20
7 Warm up massage 1 1 20
8 Warm up massage 2 1 10
9 Pressure massage 1 20
10 Kneading and pressure massage 1 20
Electrodes must be placed so that they surround the muscle segments in questi-
on. For optimal effect, electrode distance must not be greater than approx. 15cm.
The electrodes should not be applied to the anterior wall of the thorax, i.e. never
massage the left or right large pectoral muscle.
7. Application
7.1 Advice on application
If the machine is not used within 2 minutes, it switches off automatically (au-
tomatic switch-off function). When the unit is switched on again, the LCD
screen displays the menu selection and the most recently used menu flashes.
If an admissible key is pressed, there is one short beep. If an inadmissible
key is pressed, there are two short beeps.
You can pause the stimulation at any time by briefly pressing the ON/OFF
button
. To continue the stimulation, briefly press the ON/OFF button
again and set the desired impulse intensity again.
7.2 Procedure for programs TENS 1–7, EMS 1–27 and
MASSAGE 1–10 (quick start)
Select a suitable program from the program tables (p. 22–23).
Place the electrodes on the desired area for treatment (for positioning sug-
gestions see electrode positions, p. 2) and connect them to the device.
Selecting a program
Press the ON/OFF button to switch on the device.
Using the M button, navigate through the menus /
/ (Fig. 1, Example TENS display) and
confirm your selection with the E button.
Using the UP/DOWN buttons, select the desired program and
confirm your selection with the E button (Fig. 2, Example TENS
program 03).
General information
If you wish to return to the previous selection menu, press the M
button. By holding down the E button, you can skip individual set-
ting steps and start directly with the stimulation treatment.
Setting the impulse intensity
At the start of stimulation treatment, the impulse intensity of and
is set to 00 as default. No impulses are sent to the electrodes yet.
Using the INTENSITY SETTING buttons, select the desired
impulse intensity. The impulse intensity display is adjusted
accordingly (Fig. 3). The impulse intensity of
and
can be set individually.
If the program is in a pause phase, the intensity cannot be increased.
If you wish to end the stimulation treatment early, press the ON/OFF button .
Fig. 1
Fig
. 2
Fig. 3
23


Need help? Post your question in this forum.

Forumrules
1

Forum

sanitas-sem-43

Reset search

  • can I stick the electrodes high on my back? between the shoulder blades? or is this dangerous because it's too close to the heart? Submitted on 28-2-2020 at 09:10

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sanitas SEM 43 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sanitas SEM 43 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 2,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info