If the procedure runs without any problems,
the LED display remains on during the
entire charging process, until the battery is fully
charged.
When the battery is fully charged, the LED dis-
play
lights up and the LED display
goes out.
The appliance now switches automatically into
trickle charging mode.
Mode 4 “12V” (14.7V/3.8A)
This mode is used for charging 12V lead-acid
batteries with a capacity of more than 14Ah in
cold conditions or for several AGM batteries with
a capacity of more than 14Ah.
Press the button MODE selection
, to activate
Mode 4 (
). If you do not activate another
process afterwards, the electronic system will
activate together with the LED display
and starts the charging process. In this mode,
the charging current is identical to that of
“Mode 3” (
).
If the procedure runs without any problems,
the LED display remains on during the
entire charging process, until the battery is fully
charged. When the battery is fully charged,
the LED display lights up and the LED
display goes out.
The appliance now switches automatically into
trickle charging mode.
Automatic battery recognition
As soon as the charger is connected the mains
power supply, the LED display on the appli-
ance lights up.
The charger recognises the battery on the basis
of the following criteria:
if the voltage of the battery is less than 3.8V or
greater than 15V, the battery is not suitable for
charging or defective. The LED Displays
,
, and flash. The charger remains in
“Standby mode” and cannot be switched to another
charging mode by means of the MODE selection
button .
Pulse charging mode
The mode is suitable for the charging/regeneration
of empty, used and overcharged 12V lead-acid
batteries.
When the charger is connected to a battery and
the charging process starts it automatically rec-
ognises the battery voltage. It will switch to pulse
charging mode if the voltage is in the range of
7.5V ± 0.5V to 10.5V ± 0.5V.
This pulse charging process is continued until the
battery voltage has increased to 10.5V ± 0.5V.
As soon as this state is reached, the charger switches
over to the previously selected normal charging
mode.
Now the battery can be charged quickly and safely.
Most empty, used or overcharged batteries can be
regenerated and reused using this procedure.
NOTE
During the pulse charging process, the LED
display
flashes.
Trickle charging
The charge is equipped with an automatic trickle
charging function. Depending on the voltage of the
battery, the charger reacts by supplying different
charging current. The battery can remain connected
to the charger for a long period of time.
Protective function of the appliance
If a non-standard situation should occur, such as
short circuiting, a critical voltage drop during the
charging process, an open circuit or reversed
connection of the output terminals, the charger
deactivates the electronic system and immediately
switches back to its initial state to avoid damage.
If you do not activate any settings, the system
will remain in Standby mode. If the terminals are
incorrectly connected (reverse polarity), to the LED
display “Error”
also lights up.
If the appliance becomes too hot during charging,
the power output is automatically reduced. This
also protects the appliance from damage.
9


Need help? Post your question in this forum.

Forumrules
1

Forum

parkside-ulg-3.8-b1---ian-113043

Reset search

  • Hello,
    I am using this charger to continueously charge a (car-)battery which I am using to feed some outdoor LED lighting at night.
    Since a few weeks I sometimes see the intensity of the light go up and down.
    When I look at the charger, I see that the Red Led indicator "Charging" and the Green Led indicator "Fully Charged" flash alternately!
    When I then remove the charger from the power for one day, the other day it is functioning normally again.
    But after a few days it happens again!
    Can somebody tell me, what's the cause of this "flashing"?
    Wil van Woerkom (The Netherlands)
    Email address: wvwoerkom@rolluik-deur-specialist.nl Submitted on 22-5-2022 at 13:18

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside ULG 3.8 B1 - IAN 113043 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside ULG 3.8 B1 - IAN 113043 in the language / languages: English, German, Dutch, Danish, French, Swedish, Finnish as an attachment in your email.

The manual is 0,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info