5 Diagnostics
5-4 NetPath 110 Users Manual - Installation Guide 980-001-0240B
November
2000
Device
Status / Test
The Device Status / Test screen provides base module status and access to system tests.
The Device Status / Test screen is shown in Figure 5-3.
Fi
g
ure 5-3 Device Status/Test Screen
Name - Devices ID as defined in units Device Configuration.
Facility ID - Network Facility ID as defined in units CSU Interface Configuration.
Netw Port Fault - Displays (blank) or the highest priority Fault causing a disruption
of the data path.
Refer to the Appendix in this manual for a list and description of all fault
displays.
External Set Test - Displays (blank) or highest priority Test (externally activated
loopback) causing a disruption of the data path or other operational disruption of the
unit.
Refer to the Appendix in this manual for a list and description of all fault
displays.
Ckt Under Test - Selects circuit to be tested. Setting reverts to Network at logout.
NOTE: Changes to this setting while a selected test is active will force the test to
be cleared without any warning. Changes to this setting will not affect an
External Set Test.
Test Mode - Allows selection of the mutually exclusive test modes shown in
Table 5-2, based on the Ckt Under Test selection.
***************************** Device Status / Test *****************************
Name: F@43802
Netw Port Fault: Facility ID: NONAME
External Set Test:
Test Mode [T=]
Ckt Under Test [C=] >>1) Clear<<
>>1) Network<< 2) Line Lp to Netw
2) User 3) Payld Lp to Netw
4) Send LoopUp
5) Send LoopDn
6) QRSS to Netw
User Ckt Status 7) Alt Ones to Netw
RTS/DTR/LL/Pwr: On /On /Off/On 8) 2047 to Netw
Frame Fault: 9) Zero to Netw
10) Line Lp to CPE
BERT: Blocks Sent: , , Block Errors: , , BlkErr Rate: 0.00E+00
Test Duration: 00:00:00
ResetTest[RT] InjectErr[IE secs] RebootExt[RE secs]
Help[?] Close[X] AutoUpdate[AU]
>
71


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Paradyne FrameSaver NP 110 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Paradyne FrameSaver NP 110 in the language / languages: English as an attachment in your email.

The manual is 1,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info