458602
54
Zoom out
Zoom in
Previous page
1/175
Next page
4 Operation
980-001-0240B FrameSaver NP 110 Users Manual - Installation Guide 4-13
November
2000
User Port Settings
Data Rate - Displays the data rate for the User Circuit which results from the
settings for DS0 Assignments and the DS0 Format.
4. DS0 Format - Selects 56K or 64K mode for all the DS0s in the User Circuit.
5. Port TxD Clk - Configures the User Port interface to clock in the Tx data based
on either the DCE (this units) supplied clock, or the DTE (cable loop or router)
supplied clock.
Network Port Settings
6. Facility ID - Enter alphanumeric string to identify facility on other screens.
7. Build Out - Selects the Line Build-Out value for the T1 line connection.
8. Framing - Selects T1 Framing format to be used.
NOTE: ANSI or AT&T are ESF format, SF includes D4.
9. Ones Dens - Selects the Ones Density format to be used.
10.Clock Source - Defines which clock source is used for internal FrameSaver NP
timing.
11.Link Err Thres - Disables or sets the threshold for the CSU Threshold Alarm. An
alarm is declared when the Near End - Errored Seconds plus Unavailable Seconds
equals or exceeds the threshold in the current 15-minute interval.
Commands
Help [?] - Advances to Help for CSU / DTE Configuration screen.
Save [SA] - Saves parameters and returns to System View screen.
Cancel [X] - Returns to System View screen without saving changes.
Save the CSU / Interface Configuration changes when they are all set correctly by en-
tering SA followed by ENTER. This will also return the user to the System View
screen.
Proceed to Frame Manager Configuration, selecting [FC] by typing FC followed
by ENTER.
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Paradyne FrameSaver NP 110 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Paradyne FrameSaver NP 110 in the language / languages: English as an attachment in your email.

The manual is 1,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info