OC1 OPERATING MANUAL
© 2002 Design, 2009 Doc. No. 12-2761-r04 (9/6/11)
UPLOADING SETTINGS AND DOWNLOADING DATA
The Settings Upload portion of the Oceanlog PC Interface program can be used to set/change the OC1’s Main Time, Date, Set A
group (Alarms), and Set U group (Utilities) using the same Interface System. The Set F group (FO2) and FREE Mode Alarms must
be entered using the OC1's button controls.
Information available for retrieval (download) from the OC1 to the Download portion of the program includes dive number, SI,
max depth, EDT, start date/time, lowest temperature, sampling rate, dive profile, OC1's Set Points, pressure, ATR, O2BG, TLBG,
and Gas Switching events/pressures.
Prior to attempting to download data from your OC1 or upload Settings to it, review the Help section of the interface program.
Recommended is to print those sections of Help that you consider appropriate for your Interface activities.
A USB Driver is provided on the Oceanlog CD as part of the Interface System.
The OC1 is configured with a Data Port located on the side (Fig. 158a) that enables it to be connected to a PC through a USB
port using the special Interface Cable supplied.
To connect the PCI Cable to the OC1:
> position the connector with the red dot at 12 o'clock.
> align the pins of the cable connector with the holes in the data port and press the connector into the port (Fig. 159A).
> turn the connector clockwise until the red dot is at 1 o'clock and it locks in (Fig. 159B), then release it.
The OC1 checks for a connection to the Data Port once every second while the Watch Default Time is displayed. Checks are not
made if the Wet Activation contacts are wet.
When the PC Interface cable is plugged in, the graphic PC COMM is displayed with a 2 minute countdown timer that runs until
the connection is confirmed, then the graphics PC COMM CONNECTED are displayed until completion of the upload or down-
load operation.
PC requirements:
• IBM
®
, or compatible, Personal Computer with USB Port
• Intel
®
Pentium 200 MHz or better microprocessor
• Microsoft
®
Windows
®
2000, XP, Vista, or 7
• Super VGA card or compatible video graphics adaptor (256 color or greater) with a minimum 800 X 600 pixel screen area
of display settings
• 16MB of available RAM
• 20MB of available hard drive storage
• Mouse
• CD Rom drive
• Printer
For software updates, refer to the Oceanic web site at -
www.OceanicWorldwide.com
For support, call OceanLog Support toll free at -
(866) 732-7877, 8 Am to 5 Pm USA Pacific time.
Fig. 158 - OC1 DATA PORT
a
Fig. 159B - PCI CABLE
(turn dot to 1 o'clock)
Fig. 159A - PCI CABLE
(insert with dot at 12 o'clock)
dot
dot
TIMER
(counting down)
PCI CABLE
(connection sensed)
58


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic OC1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic OC1 in the language / languages: English as an attachment in your email.

The manual is 8,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic OC1

Oceanic OC1 User Manual - English - 180 pages

Oceanic OC1 Additional guide - German - 2 pages

Oceanic OC1 Quick start guide - German - 2 pages

Oceanic OC1 User Manual - German - 68 pages

Oceanic OC1 Additional guide - French - 2 pages

Oceanic OC1 Quick start guide - French - 2 pages

Oceanic OC1 User Manual - French - 68 pages

Oceanic OC1 Additional guide - Italian - 2 pages

Oceanic OC1 User Manual - Italian - 68 pages

Oceanic OC1 User Manual - Turkish - 180 pages

Oceanic OC1 User Manual - Spanish - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info