709124
18
Zoom out
Zoom in
Previous page
1/134
Next page
Further hand transmitters (up to a maximum of 30)
can be programmed.
Menu stage 2: Programming the light
function for the hand transmitter
Press key briefly and figure 1 will be displayed.
Press key once again and figure 2 will be
displayed.
Press the second button at the transmitter with which
the 4-min light is to be switched on. As soon as the
code has been read in, the red point display (a) will
flash 5 times to acknowledge the entry. Figure 0 will
be displayed. Menu finished.
Deleating all the hand transmitters programmed
for the operator:
Plug in the operators main plug while pressing
button .
Menu stage 3: Setting / adjusting the top end-
of-travel position
Keep button pressed for 3 seconds. Number 3
appears in the display 17a.
Wait a short while until the 3 starts flashing.
Press button and make sure that the door travels in
the OPEN direction.
!
If the door closes in the wrong direction, after
having pressed , keep button pressed for
another 3 seconds. 3 flashes briefly. The
travelling direction is altered.
Now travel by pressing button into the desired door
end position OPEN 17b.
By pressing button , the position can be corrected
into direction CLOSE.
Once the desired OPEN end-of-travel position has
been reached, press button . The operator stores
the OPEN end-of-travel position and 4 appears in
the display.
Menu stage 4: Setting / adjusting the bottom
end-of-travel position
Wait a short while until 4 starts flashing.
Press button . The operator causes the door to
travel in the CLOSE direction as long as the button is
pressed. The position can be altered to the OPEN
direction via button . Once the desired CLOSE end-
of-travel position has been reached, press button .
The operator stores the CLOSE end-of-travel
position and 0 appears in the display.
Force-learning cycle
!
We recommend setting the suitable door type in
menu stage 8 prior to the force-learning cycle.
During this opening and closing cycle, the
operator learns the force required to open and close
the door. The cyclesA force limit does not apply!
must not be interrupted. During these cycles must
not be interrupted. During these cycles 0 appears
in the display.
- Press button . The operator causes the door to
open until the top end-of-travel position has been
reached.
- Now press button again. The operator causes
the door to close until the bottom end-of-travel
position has been reached.
- After approx. 2 seconds, 0disappears.
Checking the force limit device
- Position the force-measuring device
(dynamometer) in the closing area.
(If a measuring device is not available, use, for
example, the operators cardboard box)
- Start the door from the OPEN end-of-travel
16
17
18
19
20
position.
- The door travels towards the obstruction, stops
and re-opens.
If the door springs were altered, the force-learning
operation must then be repeated:
Call up menu stage 5 and keep button depressed
for 3 seconds. A "0" is displayed. Then carry out
force-learning operations as explained under point
19.
Special settings
In order to access the menus for the special settings,
keep key pressed for 3 sec until figure 3 is
displayed. Press key to by-pass menu step 3.
Now keep key pressed for 3 sec until figure 5 is
displayed. Press key to by-pass menu steps.
Menu stage 5: The opening force limit
If you have previously quit the setting menu, press
button for 3 seconds until 3 appears. Then press
button twice until 5 appears.
After approx. 2 seconds, the display flashes showing
the set value of the opening force limit. The force limit
setting can be increased for decreased via buttons
and .After setting the value, press button .
The display shows 6.
Menu stage 6: The closing force limit
After approx. 2 seconds, the display starts flashing,
and the set value for the closing force limit is
displayed.
The force limit setting can be increased or decreased
via buttons and .
After setting the value, press button . 0 appears
in the display.
Finally, check the force settings, and, if necessary,
repeat the setting procedure.
The maximum force at the main closing edge must
not exceed 150 N!
Menu stage 7: Light phases
Press button . 7 appears in the display.
Menu Light Warning 24V
value phase phase
0 60 s - 60 s
1 120 s - 120 s
2 240 s - 240 s
3 0 s - 0 s
4 0 s 3 s 0 s
5 60 s 3 s 0 s
6 120 s 3 s 0 s
7 60 s 0 s TAM
8 120 s 0 s TAM
9 240 s 0 s TAM
When the advance warning time is set, the light and
24 V will be switched on before the drive starts
running.The factory setting is 1.
TAM: OPEN signal, when the door is not closed 24V
are available for signalling.
Menu stage 8: Door fitting
Press button . 8 appears in the display.
Menu Start Stop Start Stop
value open open closed closed
0 0 0 0 0
1 15 0 15 0
2 0 15 0 40
3 15 15 15 35
4 25 30 25 40
5 15 15 15 55
6 15 15 15 15
7 35 35 65 45
8 55 15 15 100
9 only soft run
These values correspond to the soft runs
measured in cm at the carriage.
Menu stage 9: special functions
Push button .9is displayed.
Menu Operating mode
value
0 Normal operation
1 Normal operation with ventilation
position
The ventilation position can be initiated by
pressing the second push button on the
hand transmitter or via the signal 112
internal push button (accessory).
2 Partial opening of side sectional doors
Partial opening of approx. 1m can be
initiated by pressing the second push
button on the hand transmitter or via the
signal 112 internal push button
(accessory).
Advice: The 2nd push button of the transmitter has
to be teached-in again after changing the operation
mode.
Internal impulse generators
The cover on the control unit is used as an impulse
generator for opening and closing from inside the
garage. Briefly press the cover and the operator
starts up .
Disengagement
The operator is equipped with a quick release. By
pulling the pull cord with knob , the operator can22a
be permanently disengaged from the door . 8 is22b
displayed.
The motor head can be re-engaged at any point
between the two limit switch actuators. To lock in
place, press down lever .22c
Installation on LH side of door
If favoured by the structural conditions on site, the
operator can also be installed on the left-hand side
ck on the other side .23c
23a. Loosen bolts on motor head with wrenches (SW
10 and 17mm) and screw them back on the23b
other side .23c
Low-mounted control unit
If the control unit cannot be positioned directly
underneath the track , the coiled cable can then24a
be routed to the motor head using the supplied
second cable clamp and the punched tape . The24b
extendible part of the coiled cable may be stretched
by a maximum of factor 3 and the permanently laid
part by a maximum of factor 7.
If the coiled cable is not long enough, the extension
set (accessory) should be used.
Connection for wicket door contact
The option of connecting the wicket door contact
to drive unit is an advantage.
- Remove housing .25a
- On the white plastic component, break out the
side wall towards the door .25b
- Route cable from wicket door contact over the
lifting arm and fasten with cable binder .25c
- Remove jumper from terminal block and25d
insert cable .25e
- Place housing back on again and screw down
.25f
Check: Open wicket door, "8" is displayed.
21
22
23
24
25
Retain these installation, operating and maintenance instructions for the full duration of the operators service life!
GB
18


Need help? Post your question in this forum.

Forumrules
1

Forum

novoferm-novoport-2016

Reset search

  • door open once by remote control after than stop with function Submitted on 28-6-2023 at 10:56

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Novoferm NovoPort 2016 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Novoferm NovoPort 2016 in the language / languages: All languages as an attachment in your email.

The manual is 9,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info