709124
19
Zoom out
Zoom in
Previous page
1/134
Next page
Operating Instructions
Information regarding the operating instructions
These operating instructions describe how to use the
product properly and safely. The safety advice and
instructions as well as the local health and safety
regulations and general safety regulations for the
range of use must be observed.
All persons using the door system must
be shown how to operate it properly and
safely.
- When the operator is being actuated, any
opening and closing phases must be
monitored.
- Keep hand transmitters out of the reach of
children.
- It must be ensured that neither persons nor
objects are located within the door's range of
travel.
Functional sequence
The garage door operator can be actuated by push-
button on the control unit (figure ) or by other23
impulse generators, such as hand transmitters, key
switches etc. It is only necessary to generate a short,
sharp impulse.
- Initial impulse:
Operator starts up and causes the door to travel
to the set OPEN or CLOSE end-of-travel
positions.
- Impulse generated whilst the door is in motion:
Door stops
- A new impulse:
Door continues to move but in the opposite
direction.
Internal safety device
If the closing door encounters an obstruction, the
operator stops and causes the door to open to its top
end-of-travel position in order to clear the
obstruction.
During the last 2 seconds of closing, the door only
opens slightly, this being sufficient to clear the
obstruction but otherwise preventing anyone from
being able to see inside the garage.
If the opening door encounters an obstruction, the
operator stops immediately. The door can be closed
again by generating a new impulse.
External safety devices
- Wicket door contact STOP A
An open wicket door stops the operator
immediately or prevents it from starting up.
- Photocell defective (STOP B)
If the photocell is interrupted whilst the door is
closing, the door stops and reverses direction.
An interruption whilst the door is opening has no
effect.
Quick release
When altering settings or making adjustments, in the
event of a power failure or malfunctions, the door can
be disengaged from the operator by actuating the
pull cord with knob on the lifting arm (figure ), so22a
that it can be operated manually.
To resume operation of the operator, press the lever
on the motor head (figure ) and the operator re-22c
engages.
If the door is to be operated manually over a longer
period of time, then the door latches which were
taken out of service for power operation, must be
refitted, otherwise the door will not be latched when
closed.
Lighting
The lighting switches on automatically whenever a
start impulse is generated and switches off again
after the set time phase (factory setting approx. 60
seconds).
A second button on the hand transmitter can be
programmed for 4-minutes light (figure ). When16
the button on the hand transmitter is pressed, the
light switches on independent of the motor and
switches off again after approx. 4 minutes.
Signal light
If a signal light for signalling the opening and closing
phases is installed, this flashes together with the
lamp in the operator as soon as a start impulse is
generated. The operator starts with a time delay in
accordance with the set early warning phase (see
Special Settings in menu stage 7).
Hand transmitters
- Programming further hand transmitters:
See menu stages 1 and 2 (figures and ).15 16
- Changing the battery: slide back the battery
compartment cover on the hand transmitter.
Take out the battery.
- Insert a new battery. Be sure to pole correctly!
Slide the cover back on.
Empty batteries must be disposed of separately
(toxic waste)!
Further operating modes
In menu 9, another operating mode can be chosen.
For the setting applying to menu 9, see parantheses.
Normal operation for ventilation position (1)
The ventilation position is designed to allow
ventilation of the garage. For this, the door is opened
approx. 10 cm.
Actuation as for normal operation.
By pressing the 2 button on the hand transmitter or
nd
generating an impulse via another device, the door
can be brought into the ventilation position from any
given position.
The gate will close automatically after 60 min or can
be closed earlier by any impulse transmitter.
Operation on a side-opening sectional door (2)
Instead of opening the door fully, the door can be
partially opened by approx. 1 m in order to provide
access to the garage.
By pressing the 2 button on the hand transmitter or
nd
generating an impulse via another device, the door
can be brought into the partially open state from any
given position.
Maintenance / Checks
For your own safety we recommend
that the door system be checked by
a
specialist after initial installation and
then regularly at intervals of 1 year
minimum.
Monitoring the force limit
The operator control unit features a dual-processor
safety system to monitor the force limit.
The integral force cut-out is automatically tested at
each end-of-travel position.
The door system must be checked before initial
operation and at least once a year thereafter, In the
process, the force limiting device (figure ) must be20
tested!
If the closing force is set tooCAUTION!
high, this can result in injury to persons and
damage to property.
The opening force can be re-adjusted in menu stage
5, the closing force in menu stage 6.
Cycle counter
The cycle counters stores the number of opening or
closing cycles performed by the operator.
In order to read out the meter, keep the
button pressed for 3 seconds until a number is
displayed. The display throws out the values
beginning from the highest decimal place down to
the lowest one after another. In the end, a horizontal
line is displayed. Example: 3456 cycles, 3 4 5 6 -
Retain these installation, operating and maintenance instructions for the full duration of the operators service life!
GB
19


Need help? Post your question in this forum.

Forumrules
1

Forum

novoferm-novoport-2016

Reset search

  • door open once by remote control after than stop with function Submitted on 28-6-2023 at 10:56

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Novoferm NovoPort 2016 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Novoferm NovoPort 2016 in the language / languages: All languages as an attachment in your email.

The manual is 9,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info