Important:
This option resets all of the following settings and
resets them to the manufacturer’s default settings.
Speed and distance are related. For example, if knots
are chosen as the speed units, then distance is
always measured in nautical miles.
To reset the fishfinder to the manufacturer's default
settings, power off the fishfinder. Then hold
and
power on while holding it.
The message “RESET TO FACTORY DEFAULTS?”
appears. Press
to select YES or NO. Then press
or
to reset the trip log and exit.
GENERAL
Auto Gain ....................................................... ON
Auto Range .................................................... ON
Manual Gain .......................................................5
Bottom Lock ................................................... ON
Key Beep ........................................................ ON
Contrast ............................................................. 6
Backlighting ........................................................6
UNITS
Temperature ..................................................... °F
Depth ........................................................... Feet
Speed .............................................................. KN
Fuel ......................................................... US Gal.
4-10 Resetting to Factory Defaults
ALARMS
Shallow Alarm .............................................. OFF
Shallow Alarm Value .....................................10 ft
Deep Alarm .................................................. OFF
Deep Alarm Value ......................................... 60 ft
Fish Alarm .................................................... OFF
Temp. Change Alarm ................................... OFF
Temp. Change Alarm Value........................ 5.0 °F
Temp. Alarm ................................................. OFF
Temp. Alarm Value ...................................... 80 °F
Low Battery Alarm ........................................ OFF
Battery Alarm Value .............................. 11.5 Volts
Low Fuel Alarm .................................... 5 US Gal.
FISH SYMBOL .......................................
INSTALL
Keel Offset ................................................... 0.0 ft
Num. Engines ....................................................0
Tank size ............................................ 18 US Gal.
Flow Filter ................................................ 10 sec.
Setting the Flow Filter Period
Normally engines do not draw fuel from the tank at a
steady rate. To give a stable fuel flow reading, the
TRACKER calculates the flow values by taking several
measurements and averaging them. The flow filter
sets the period over which the fuel flow is averaged,
and can be set from 1 to 255 seconds or Off.
Set the flow filter to the lowest value which give a
stable flow. Usually a value of 10 to 15 seconds will
give a satisfactory result for two-stroke carburettor
engines. Electronic fuel injected and four-stroke
engines may require a larger value.
This setting affects the Flow rate and Economy displays.
It does not affect the fuel used measurement.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Navman FISH 4200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Navman FISH 4200 in the language / languages: English as an attachment in your email.

The manual is 0,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info