610981
6
Zoom out
Zoom in
Previous page
1/8
Next page
06
HI-LINE LV Fan Convector
10.0 Technical Data
Heating Performance Data
Model Fan Speed
Temperature Difference (°C)
Heat Output (watts) Heat Output (Btu/h)
352 541 734 930 1128
645 991 1344 1702 2065
Normal
Boost
7-4
1201 1846 2504 3173 3849
2201 3381 4586 5807 7046
20° 30° 40° 50° 60° 20° 30° 40° 50° 60°
Noise Levels
Heat outputs tested in accordance with BS 4856 Part 1.
Flow rate 340 ltr/h (75 gal/h).
Flow Rate Correction Factors:
455 ltr/h (100 gal/h) multiply by 1.06.
227 ltr/h (50 gal/h) multiply by 0.96.
113 ltr/h (25 gal/h) multiply by 0.85.
Fan Speed
Sound Pressures at 2.5m (dBA)
Normal 16.6
Boost 32.5
Approximate Hydraulic Resistance through
Fan Convectors
Litres/h
455
340
227
113
mm wg
1084
798
350
134
kPa
9.4
7.7
3.5
1.4
Weight, Water Content and Motor Power
Motor
Power (W)
Water
Content (l)
Unpacked Weight
(kg)
11.0 Operating Instructions
The HI-LINE LV is fitted with a fan speed and off selector switch.
Ensure that the electrical supply is switched on.
Heating will only be provided when the central heating boiler is
on, the pump is running and the system water temperature is
greater than 43°C. Ensure boiler is on, and set timer, boiler
controls and room thermostats as necessary.
Turn remote room thermostat (if fitted) to a high setting.
Set fan speed control to position I.
The unit will now run on low fan speed.
The low speed setting is recommended for normal operation
with the high speed for boost heating (position II) when required.
Low Limit Operation
A low limit thermostat fitted to the HI-LINE LV will ensure that
the fan stops after the heating system is switched off and the
water flow stops. If left in an operating position the unit will
automatically restart when the heating system is reheated.
Off Position
Set the fan speed selector switch to the off (O) position.
12.0 Troubleshooting
Once installed this fan convector becomes part of a complete
heating system that will generally include a boiler, pump, other
emitters such as radiators and fan convectors, and a number of
heating controls, dependent on system complexity. An apparent
problem with this unit may be the result of system controls being
incorrectly set and can be solved easily without calling out your
installer or MYSON Service. Before calling your installer or
MYSON Service, please carry out the checks listed opposite.
Note: If you call out MYSON Service to a fault detailed opposite,
or to repair a fault caused by incorrect use, a call out charge will
be made.
Noise levels tested in accordance with EN 23741.
Test Pressure 20bar (2MPa)
Maximum Working Pressure 10bar (IMPa)
Water connections 15mm
Electrical supply to transformer 230V - 50Hz
30 0.3 7.4
xxxxxx HiLine LV manual_Layout 1 27/06/2011 09:39 Page 7
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Myson HI-LINE LV Fan Convector 7-4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Myson HI-LINE LV Fan Convector 7-4 in the language / languages: English as an attachment in your email.

The manual is 0,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info