■Fan speeds which can be set vary depending on the models of IU.
■When the Auto is selected, the fan speed is changed automatically depending on the capacity.
Note that Auto is not displayed and cannot be set when SC-SL2 or SC-SL3 is connected.
Change the fan speed
Menu
Direction
Cooling
16:14
(Mon)
F1: High powerF2: Energy-saving
Timer
Now stopping.
Set temp
Change the fan speed
Back
OutdoorRoomR/C
Select the fan speed.
Auto
Changing the function of the F1 or F2 switch can be performed with the F1/F2 function setting.
The following functions are set as factory settings.
You may change these settings as desired.
F1 switch …High power operation
F2 switch …Energy-saving operation
F1/F2 switch operation
You can set any of the following functions to the F1 and F2 switches.
The F1 / F2 switches act as shortcuts; it can be much easier and faster than starting an operation from the usual Menu on the TOP screen.
High power operation
The high power operation adjusts the room temperature quickly to a pleasant level by increasing the operation capacity.
The high power operation continues for 15 minutes at the maximum and returns to the normal operation automatically. When the operation mode is changed, the high power
operation returns to the normal operation, too.
High power operation must be set to theF1or F2switch.
High power operation is set to the F1switch as the factory setting.
1 Push the F1 ( F2 ) switch to start the high power operation.
■Operation will start when the F1 (F2) switch is pushed, even if Run/Stop switch is off.
■High power operation is only allowed when Heating or Cooling is selected for the operation mode.
Message “In operation for high power.” is displayed on the R/C screen, and “—, —°C” is displayed on the Set temp button
during the high power operation.
■Set temp and change fan speed operations are disabled during high power operation.
2 High power operation is terminated when you perform one of the following.
・ When you terminate through a Run/Stop operation
・ When you change the operation mode
・ When15 minutes have elapsed since the high power operation started
・ When you terminate the high power operation with the F1 ( F2 ) switch
Menu
Direction
Cooling
15:50
(Mon)
F1: High power
Timer
In operation for high power.
Set temp
F2: Energy-saving
1 Push the F1 ( F2 )switch to start the energy-saving operation.
■Operation will start even if you press the F1 (F2) switch while the unit is stopped.
■Energy-saving operation is only allowed when Heating, Cooling or Auto is selected for the operation mode.
Message “In operation for energy-saving.” is displayed on the screen during the energy-saving operation. Set temp is xed at
“28.0°C” in the cooling operation or “22.0°C” in the heating operation. Set temp shows “- -°C” in the automatic operation mode.
■Set temp cannot be changed during the energy-saving operation. If it is attempted, a message “Invalid request” is displayed on the screen.
2 Energy-saving operation is terminated when you perform the following.
・ When you terminate through a Run/Stop operation
・ When you change the operation mode
・ When you terminate the energy-saving operation with the F1 ( F2 ) switch
Energy-saving operation
Use this operation to save energy. Set temp is fixed at 28°C in the cooling operation or 22°C in the heating operation. Since the capacity is controlled automatically based on the
outdoor temperature, energy can be saved without losing comfort.
Energy-saving operation must be set to theF1or F2switch.
Energy-saving operation is set to the F2switch as the factory setting.
Menu
Direction
Auto
16:04
(Mon)
F1: High powerF2: Energy-saving
Timer
In operation for energy-saving.
Set temp
・High power operation ・Energy-saving operation ・Silent mode control
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Mitsubishi RC-EX3 - REMOTE CONTROL at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Mitsubishi RC-EX3 - REMOTE CONTROL in the language / languages: English as an attachment in your email.
The manual is 6.18 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
Others manual(s) of Mitsubishi RC-EX3 - REMOTE CONTROL
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.