Audio Scope
The TX/RX audio can be displayed on an “audio scope screen”
where a spectrum scope and an oscilloscope are displayed as well
as on a “multi scope screen” where a reduced display of the
bandscope appears at the top together with the “audio scope
screen”.
Displaying the Audio Scope
Press and hold [SCP] to display the Audio Scope
screen.
Pressing and holding [SCP] each time toggles the display
between “Audio Scope” and “Bandscope”.
Audio Scope Screen
Left: Spectrum scope
Right: Oscilloscope
.
Switching the Audio Scope Display Type
1 Display the Audio Scope screen.
2 Press [SCP].
Pressing [SCP] each time switches the selection in the
following sequence.
“Audio Scope screen”
“Multi Scope screen”
No scope display (ends scope display)
Multi Scope Screen
Top: Reduced bandscope display
Left: Spectrum scope
Right: Oscilloscope
.
3 Press [ESC] to end the display.
Switching the Spectrum Scope Attenuator
By switching the attenuator for the spectrum scope, the spectrum
display can be adjusted to a level that is easy to see.
Press F2 [ATT].
Pressing F2 [ATT] each time switches the attenuator.
Setting Value Off (default)/ 10 dB/ 20 dB/ 30 dB
Pressing and holding F2 [ATT] each time switches the
options in the reverse sequence.
The current setting is displayed at the top of the spectrum
scope.
Switching the Display Frequency Span of the
Spectrum Scope
The display frequency span of the spectrum scope can be
configured to 3 kHz or 8 kHz. Configure the display frequency span
to an appropriate setting according to the filter band setting and
frequency to observe.
Press F3 [SPAN].
Pressing F3 [SPAN] each time toggles the span between “3
kHz (default)” and “8 kHz”.
.
Display when 8 kHz is selectedDisplay when 3 kHz is selected
Switching the Oscilloscope Level
By switching the vertical level of the oscilloscope, the amplitude of
the waveform can be adjusted to a size that is easy to see.
Press F6 [LEVEL].
Pressing F6 [LEVEL] each time switches the level.
Setting Value 0 dB (default)/ -10 dB/ -20 dB/ -30 dB
Pressing and holding F6 [LEVEL] each time switches the
options in the reverse sequence.
The current setting is displayed at the top of the oscilloscope.
Switching the Sweep Time
Switching the sweep time of the oscilloscope alters the time range
of the oscilloscope display. The sweep time can be adjusted
according to the status of the signal to be observed.
Press F5 [TIME].
Pressing F5 [TIME] each time switches the sweep time.
Setting Value
1 ms/ Div/ 3 ms/ Div/ 10 ms/ Div/ 30 ms/ Div/ 100
ms/ Div (default)/ 300 ms/ Div
Pressing and holding F5 [TIME] each time switches the
options in the reverse sequence.
The sweep time is displayed at the bottom of the
oscilloscope.
Pausing the Audio Scope
When the waveform displayed on the Audio Scope screen is
paused, the waveform is maintained until it is unpaused. The audio
scope can be paused to enable analysis of the waveform without
being interrupted whenever the display is refreshed.
Press F4 [PAUSE] to pause the waveform display.
When the waveform display is paused, << >> is
displayed and both the spectrum scope on the left and the
oscilloscope on the right stop refreshing temporarily.
Pressing F4 [PAUSE] again cancels the paused state.
.
7 SCOPE FUNCTIONS
7-8
104


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-890S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-890S in the language / languages: English as an attachment in your email.

The manual is 21,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-890S

Kenwood TS-890S User Manual - German - 196 pages

Kenwood TS-890S User Manual - Dutch - 196 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info