683161
62
Zoom out
Zoom in
Previous page
1/196
Next page
Preamplifier
The preamplifier can be configured to one of the two options: low
gain type that places priority on IMD (PRE 1) and high gain type
that places priority on sensitivity (PRE 2).
Press F [ANT/PRE].
Pressing F [ANT/PRE] each time switches the selection in the
following sequence: “PRE 1” → “PRE 2” → “OFF”.
The preamplifier selection is stored for each antenna
selection band.
The default values are as follows.
Less than 7.5 MHz: OFF
7.5 MHz to less than 21.5 MHz: PRE 1
More than 21.5 MHz: PRE 2
RX Monitor
If weak signals are received while the squelch is closed, the signals
tend to be interrupted. Also, you may sometimes want to monitor
the condition of the RX frequency while in the CTCSS standby
state. In this case, the RX monitor is used to open the squelch
temporarily.
“RX Monitor” (Menu [0-15] to [0-31]) can be assigned to a PF key.
While the PF key that is assigned with “RX Monitor” is pressed and
held down, the squelch opens and the RX frequency can be
monitored. The RX monitor turns OFF once the key is released.
Scanning is paused while PF [RX Monitor] is pressed.
SWL (BCL) Mode
The SWL (BCL) mode is intended for SWL (Short Wave Listening)
and BCL (Broadcast Listening) by displaying the horizontal dial of
the “9R-59” communications receiver on the screen.
1 Press [MENU].
2 Press F [SWL] to display the SWL screen.
If F [SWL] is not displayed, press F [MORE].
.
3 Press [MENU] followed by F [SWL].
Returns to the normal screen.
Switching to the SWL mode is not possible while the
transverter is ON.
An indicator is not displayed if a memory channel that is
not registered is being called up.
Restrictions are applied to the following functions in the SWL
mode.
Function Status
Transmission Disabled
Sending of voice message Disabled
Decoding/Encoding Disabled
Sending of CW message Disabled
TX output power limiter Disabled
Meter switching Disabled
TX filter switching Disabled
Turning ON transverter Disabled
FM tone Disabled
Antenna tuning Disabled
Configuration of the TX
equalizer and related
settings
Disabled
Band Switching in the SWL Mode (VFO Mode)
Press F [BAND
]/ F [BAND ].
The “broadcast/meter band” is displayed when the
frequency falls within the band range. The preset broadcast
bands are shown in the table below.
Broadcast/
Meter Band
Lower Limit
[kHz]
Upper Limit
[kHz]
Default [kHz]/ Mode
LW 145 285 145
AM
MW 525 1705 525
120 m 2300 2495 2300
90 m 3200 3400 3200
60 m 4750 5060 4750
49 m 5900 6200 5900
41 m 7200 7450 7200
31 m 9400 9900 9400
25 m 11600 12100 11600
21 m 13570 13870 13570
19 m 15100 15800 15100
16 m 17480 17900 17480
15 m 18900 19020 18900
13 m 21450 21850 21450
11 m 25670 26100 25670
The band segments of the SWL mode that is preconfigured on
this transceiver are represented in a slightly different way
compared to conventional meter bands. Different band
segments are used so as to achieve wider coverage to include
the broadcast bands of the different regions and other bands.
5 COMMUNICATING AIDS
5-6
62


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-890S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-890S in the language / languages: English as an attachment in your email.

The manual is 21,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-890S

Kenwood TS-890S User Manual - German - 196 pages

Kenwood TS-890S User Manual - Dutch - 196 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info