PACKET-5
Command Name Short Description Parameter Default
LOCATION LOC
If set to EVERY, sends GPS data at intervals of the specifi ed
period (n). If set to AFTER, sends GPS data only once after
the specifi ed period (n). The unit of n is 10 seconds.
EVERY/ AFTER n
(n = 0 ~ 250)
EVERY 0
LOG LOG
Displays the list of stations which have connected to the TNC
mailbox.
−−
LPAT H L PA
Specifi es callsigns to send GPS data. Call1 is the callsign of
the destination. Call2 to call9 are callsigns of stations to be
digipeated through.
Call1 (VIA call2,
call3, ... call9)
GPS
LTEXT LT
Specifi es the content of a message to be included in GPS
data.
0 ~ 159 characters
LTMON LTM
Specifi es the interval for displaying a message determined
by LTEXT on the screen; a message appears like a received
beacon packet. The unit of the parameter is 1 second.
0 ~ 250 0
MAIL MAI
When ON and the TNC mailbox holds a message addressed
to you, outputs “Low” to the MAILLED terminal.
ON/ OFF OFF
MAXFRAME MAX
Specifi es the maximum number of packets to be transmitted
at one time.
1 ~ 7 4
MBOD MB When ON, allows the TNC mailbox to be used. ON/ OFF OFF
MCOM MCOM
When ON, causes the TNC to also monitor control packets.
When OFF, causes it to monitor only information packets.
ON/ OFF OFF
MCON MC
When ON, causes the TNC to monitor other stations while in
connection with the target station.
ON/ OFF OFF
MINE MI
Displays the list of messages, in the TNC mailbox,
addressed to you and messages that you sent.
−−
MONITOR M When ON, causes the TNC to monitor packets. ON/ OFF ON
MRPT MR
When ON, causes the TNC to display the entire digipeat list
for monitored packets.
ON/ OFF ON
MSTAMP MS
When ON, causes the TNC to display data and time
information for monitored packets.
ON/ OFF OFF
MYALIAS MYA Specifi es a callsign for using your station as a digipeater.
6 characters +
SSID
MYCALL MY Specifi es your callsign.
6 characters +
SSID
MYMCALL MYM Specifi es a callsign to be assigned to your TNC mailbox.
6 characters +
SSID
NEWMODE NE
When ON, entering a CONNECT command causes the TNC
to immediately enter the other mode.
ON/ OFF OFF
NOMODE NO
When ON, does not cause the TNC to automatically enter
the other mode. When OFF, causes it to automatically enter
the other mode as specifi ed by NEWMODE.
ON/ OFF OFF
NPAT H NPAT H
Specifi es digipeater callsigns to be added when the UISSID
parameter in a received packet is 8 or 12.
Call1, ... call7
NTSGRP NTSGRP
Specifi es a group code to be used for making a $PNTS
sentence.
0 ~ 3 characters
NTSMRK NTSMRK
Specifi es a mark number to be used for making a $PNTS
sentence.
$00 ~ $14 $00
NTSMSG NTSMSG
Specifi es a message to be used for making a $PNTS
sentence.
0 ~ 20 characters
OVERKILL OVE
Specifi es the number of old messages to be deleted when
the TNC mailbox does not accept a new message because
the memory is full.
0 ~ 255 0
PACLEN P
Specifi es the maximum length of the data portion of a
packet.
0 ~ 255 128
PACTIME PACT
If set to EVERY, sends a packet at intervals of the specifi ed
period (n). If set to AFTER, sends a packet only once after
the specifi ed period (n). The unit of n is 100 milliseconds.
EVERY/ AFTER n
(n = 0 ~ 250)
AFTER 10
PERSIST PE
Specifi es a parameter to calculate probability for the
PERSIST/SLOTTIME method.
0 ~ 255 128
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TM-D710GA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TM-D710GA in the language / languages: English as an attachment in your email.

The manual is 7,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TM-D710GA

Kenwood TM-D710GA User Manual - English - 55 pages

Kenwood TM-D710GA User Manual - German - 74 pages

Kenwood TM-D710GA User Manual - Dutch - 75 pages

Kenwood TM-D710GA User Manual - Dutch - 55 pages

Kenwood TM-D710GA User Manual - French - 77 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info