686383
11
Zoom out
Zoom in
Previous page
1/26
Next page
EN
Esc button
Use the Esc button to move to the previous menu level.
Displays
• The control panel displays show adjustable operation parameters, their values, and the
units of measure.
• During welding, display P2 shows the welding current value that is currently in use, while
display P6 shows the welding voltage.
Control knobs
• The left-hand control knob P11 allows the adjustment of the speed of wire feeding. The
selected speed is shown on the display on the left-hand side.
• The right-hand side control knob P13 allows for controlling the welding voltage in MIG
and 1-MIG processes, in which case the selected voltage is shown on the right-hand side
display, and the base current in WiseThin processes, in which case the adjustment range
is +/- 50.
These control knobs are also used for specifying the operating parameters. A parameter for
adjustment is selected with the left-hand knob, while the value of the parameter is selected
with the right-hand knob.
2.2.2 Adjusting MIG dynamics (Arc Force)
When you press button P3, you can adjust the MIG welding dynamics of the machine by
means of the right-hand knob.
When using the MIG or 1-MIG welding process, the welding dynamics setting aects the
features of the welding arc and the amount of welding spatter as shown below:
• The value 0 is the recommended basic setting.
• Use values -1...-9 if you want a softer arc and less spatter.
• Use values 1...9 if you want a rougher and more stable arc. This setting is useful when you
are using 100% CO₂ shielding gas when welding steel.
When using a WiseThin process, the welding dynamics setting aects the forming pulse as
shown below:
• Use values -1...-30 if you want a softer arc and smaller penetration.
• Use values 1...30 if you want a rougher and greater penetration.
2.2.3 Gas test
The gas test button P4 opens the gas valve without activating the wire feed or power source.
By default, gas ows for 20 seconds. The gas ow time remaining is shown on the display.
The right-hand knob allows you to set the default gas ow time, between 10 and 60 seconds,
and store the new default value in the machines memory. To stop the gas test, press the ESC
button.
2.2.4 Wire feed test
When you press the Wire inch button, P6, the wire feeder engine starts but the gas valve does
not open and the power source is not activated.
The wire feed pace is 2 m/min for the rst two seconds, and then 10 m/min.
When the button is released, the wire feeding stops. The machine automatically goes back
to the normal state after approximately 3 seconds from release of the button or immediately
when you press the ESC button.
2.2.5 Selection of liquid- or gas-cooled MIG gun
You can select a MIG gun cooled with liquid or gas by pressing buttons P3 and P4
simultaneously and holding them down for at least one second.
• When the display reads GAS, you can use a gas-cooled MIG gun with the equipment.
• When the display reads COOLEr, you can use a liquid-cooled MIG gun with the
equipment.
9
KempArc SYN 300, 400, 500, DT 400 / © Kemppi Oy / 1117
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi Kemparc SYN 500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi Kemparc SYN 500 in the language / languages: English as an attachment in your email.

The manual is 1,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info