A7 MIG Welder© Kemppi Oy 2018 1804
INTEGRATION GUIDE
6.2.16 ArcOn
This signal function indicates the status of the welding arc.
0 = Arc not established
1 = Arc established
6.2.17 GasFlowOk
This signal function indicates the status of the gas ow.
The signal is set (1) when the gas ow rate is above the
minimum level set by a user and is cleared (0) when the
gas ow is too low. The gas sensor must be enabled from
a user interface.
Gas ow below the minimum level
Gas ow above the minimum level
6.2.18 MainCurrentOn
This signal function indicates the status of the welding
power. The signal is set (1) when the power source has
turned the welding power on.
0 = Power source in standby mode
1 = Welding power on
6.2.19 CurrentOk
This signal function indicates that the welding current is
within the limits set by a user.
0 = Current below minimum or above maximum
1 = Current within the limits
This function is not implemented in the A7 MIG Welder.
The status is always OK (1).
6.2.20 MotorCurrentOk
This signal function indicates that the wire feeding motor
current is below the system limit.
0 = Motor current too high
1 = Motor current OK
This function is not implemented in the A7 MIG Welder.
The status is always OK (1).
6.2.21 WFSpeedOk
This signal function indicates that the wire feed speed is
within the limits set by a user.
0 = Wire feed speed too low or too high
1 = Wire feed speed within the limits
This function is not implemented in the A7 MIG Welder.
The status is always OK (1).
6.2.22 TouchSensed
This signal function indicates contact between the touch
tool and the welding piece. This feature is enabled and
disabled by the TouchSensorOn signal. The touch tool is
selected by the TouchSensorToolSel signal or forced from
a user interface.
0 = Touch not detected
1 = Touch detected
6.2.23 Error
This signal function indicates an error in the system (except
the gate door open error). The signal is on (1) for an error;
otherwise it is o (0). For warnings this signal remains o.
See the ErrorNumber description for more information.
For clearing this bit, the error situation must be resolved
and the error reset by means of the ErrorReset signal or
from a user interface.
0 = Warning or no error
1 = Error in system
6.2.24 CollisionDetected
This signal function indicates the collision sensor status. In
addition to this function being active, a collision detection
error (Error 53 Collision detected) will be set when a
collision is detected. The collision sensor must be on for
this function to take eect. When the collision sensor
is switched o, this signal is always in the “Collision not
detected” state.
The polarity of this signal can be set from a user interface.
High-active signal:
0 = Collision not detected
1 = Collision detected
Low-active signal:
0 = Collision detected
1 = Collision not detected
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi A7 MIG Welder 350 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi A7 MIG Welder 350 in the language / languages: English as an attachment in your email.

The manual is 5,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info