686369
46
Zoom out
Zoom in
Previous page
1/66
Next page
46
A7 MIG Welder© Kemppi Oy 2018 1804
INTEGRATION GUIDE
6.2.1 WeldingCurrent
This 16-bit function represents the average welding
current measured during the process. The value is in
scaled or non-scaled mode, depending on the user setup.
In non-scaled mode:
The minimum value is 0 A.
The maximum value is 1024 A.
The minimum step is 1 A.
In scaled mode:
The minimum value is 0 (0 A).
The maximum value is the current scaling value,
which is interpreted as 1024 A.
The minimum step is 1. The welding current is
calculated from the function value by means of
the value scaling formula.
6.2.2 WeldingVoltage
This 16-bit function represents the average welding
voltage measured during the process. The value is in
scaled or non-scaled mode, depending on the user setup.
In non-scaled mode:
The minimum value is 80 (8.0 V).
The maximum value is 460 (46.0 V).
The minimum step is 1 (0.1 V).
In scaled mode:
The minimum value depends on the scaled value
range and is interpreted as 8.0 V.
The maximum value is the voltage scaling value,
which is interpreted as 46.0 V.
The minimum step is 1. The welding voltage is
calculated from the function value by means of
the value scaling formula.
6.2.3 WeldingWireFeedSpeed
This 16-bit function represents the average wire feed
speed measured during the welding process. The value
is in scaled or non-scaled mode, depending on the user
setup.
In non-scaled mode:
The minimum value is 0 (0.0 m/min).
The maximum value is 250 (25.0 m/min).
The minimum step is 1 (0.1 m/min).
In scaled mode:
The minimum value is 0 (0.0 m/min).
The maximum value is the wire feed speed
scaling value, which is interpreted as 25.0 m/min.
The minimum step is 1. The wire feed speed is
calculated from the function value by means of
the value scaling formula.
6.2.4 MotorCurrent
This 8-bit function represents the average motor current
measured during the welding process.
The minimum value is 0 (0.0 A).
The maximum value is 100 (10.0 A).
The minimum step is 1 (0.1 A).
6.2.5 GasFlowRate
This 16-bit function represents the average gas ow rate
measured during the welding process or when the gas
valve is forced to be open. This feature requires the gas
ow sensor to be congured properly and turned on from
the user setup.
The minimum value is 0 (0.0 l/min).
The maximum value is 500 (50.0 l/min).
The minimum step is 1 (0.1 l/min).
6.2.6 ErrorNumber
This 8-bit function represents a non-zero error code if there
is a warning or an error active in the system. Otherwise
the value is zero. The error number is an enumeration that
represents the reason for the error. Refer to the A7 MIG
Welder operating manual for more information about
reasons for errors. See also the description for the Error
status signal. To clear this value, one must resolve the
error situation and reset the error by using the ErrorReset
control signal or from a user interface.
The minimum value is 0 (no error).
The maximum value is 255.
The minimum step is 1.
46


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi A7 MIG Welder 350 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi A7 MIG Welder 350 in the language / languages: English as an attachment in your email.

The manual is 5,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info