If there is no refrigerant piping embedded in
the wall, do the following:
1. Based on the position of the wall hole relative to
the mounting plate, choose the side from which the
piping will exit the unit.
2. If the wall hole is behind the unit, keep the knock-out
panel in place. If the wall hole is to the side of the
indoor unit, remove the plastic knock-out from that
side of the unit (See figure below). This will create a
slot through which your piping can exit the unit. Use
needle nose pliers if the plastic panel is too difficult to
remove by hand.
2. Use the holder at the back of the unit to prop up
the unit, giving you enough room to connect the
refrigerant piping, signal cable, and drain hose.
Open the cover
and unscrew the
screws
Unscrew the
screws
Model B
Use the holder at the back of the
unit against on the mounting
plate to prop up the unit
3. Use scissors to cut down the length of the insulating
sleeve to revel about 40mm (1.57in) of the refrigerant
piping. This serves two purposes:
To facilitate the Refrigerant Piping Connection
process.
To facilitate Gas Leak Checks and enable you to
check for dents.
4. Use the holder at the back of the unit to prop up
the unit, giving you enough room to connect the
refrigerant piping, signal cable, and drain hose.
5. Connect the indoor unit's refrigerant piping to
the connective piping that will join the indoor and
outdootr units. Refer to the Refrigerant Piping
Connection section of this manual for detailed
instructions
6. Based on the position of the wall hole relative to the
mounting plate, determine the necessary angle of
your piping.
7. Grip the refrigerant piping at the base of the bend.
8. Slowly, with even pressure, bend the piping towards
the hole. Do not dent or damage the piping during
the process.
Knock-out Panel (cut
depending on the actual
size needed)
If need to cut the big size plastic
panel, cut as shown above.
Step 3: Connect drain hose and refrigerant piping
(refer to Refrigerant Piping Connection section
of this manual for instructions).
Step 4: Keep pipe connection point exposed to
perform the leak test (refer to Electrical Checks
and Leak Checks section of this manual).
Step 5: After the leak test, wrap the connection
point with insulation tape.
Step 6: Remove the bracket or wedge that is
propping with insulation tape.
Step 7: Using even pressure, push down on the
bottom half of the unit. Keep pusnhing down until
the unit snaps onto the hooks along the bottom
of the mounting plate.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun Prodigy Pro Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun Prodigy Pro Series in the language / languages: English as an attachment in your email.

The manual is 4.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun Prodigy Pro Series

Kaysun Prodigy Pro Series User Manual - German - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info