771410
24
Zoom out
Zoom in
Previous page
1/41
Next page
CORRECT
Make sure there are no kinks
or dent in drain hose to ensure
proper drainage.
NOT CORRECT
Kinks in the drain hose will
create water traps.
NOT CORRECT
Kinks in the drain hose will
create water traps.
NOT CORRECT
Do not place the end of the drain
hose in water or in containers
that collect water. This will
prevent proper drainage.
Page 24
PLUG THE UNUSED DRAIN HOLE
To prevent unwanted leaks you
must plug the unused drain hole
with the rubber plug provided.
Step 5: Connect drain hose
By default, the drain hose is attached to the left-hand
side of the unit (when you're facing the back of the
unit). However, it can also be attached to the right-hand
side. To ensure proper drainage, attach the drain hose
on the same side that your refrigerant piping exits the
unit.
NOTE: In some locations of US, if the machine has
installed the conduit panel, please choose right-hand
side drainage.
Wrap the connection point firmly with Teflon tap to
ensure a good seal and to prevent leaks.
Remove the air filter and pour a small amount of
water into the drain pan to make sure that water
flows from the unit smoothly.
NOTE ON DRAIN HOSE PLACEMENT
Make sure to arrange the drain hose according to the
folllowing figures.
DO NOT kink the drain hose.
DO NOT create a water trap.
DO NOT put the end of drain hose in water or a
container that will collect water.
BEFORE PERFORMING ANY ELECTRICAL
WORK, READ THESE REGULATIONS
1. All wiring must comply with local and national
electrical codes, regulations and must be installed
by a licensed electrician.
2. All electrical connections must be made according
to the Electrical Connection Diagram located on
the panels of the indoor and outdoor units.
3. If there is a serious safety issue with the power
supply, stop work immediately. Explain your
reasoning to the client, and refuse to install the
unit until the safety issue is properly resolved.
4. Power voltage should be within 90-110% of
rated voltage. Insufficient power supply can
cause malfunction, electrical shock, or fire.
5. If connecting power to fixed wiring, a surge
protector and main power switch should be
installed.
6. If connecting power to fixed wiring, a switch or
circuit breaker that disconnects all poles and has
a contact separation of at least 1/8in (3mm) must
be incorporated in the fixed wiring. The qualified
technician must use an approved circuit breaker
or switch.
7. Only connect the unit an individual branch circuit
outlet. Do not connect another appliance to that
outlet.
8. Make sure to properly ground the air conditioner.
9. Every wire must be firmly connected. Loose wiring
can cause the terminal to overheat, resulting in
product malfunction and possible fire.
10. Do not let wires touch or rest against refrigerant
tubing, the compressor, or any moving parts
within the unit.
11. If the unit has an auxiliary electric heater, it must
be installed at least 1 meter (40in) away from any
combustible materials.
12. To avoid getting an electric shock, never touch
the electrical components soon after the power
supply has been turned off. After turning off the
power, always wait 10 minutes or more before
you touch the electrical components.
WARNING
BEFORE PERFORMING ANY ELECTRICAL OR
WIRING WORK, TURN OFF THE MAIN POWER TO
THE SYSTEM.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun Prodigy Pro Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun Prodigy Pro Series in the language / languages: English as an attachment in your email.

The manual is 4.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun Prodigy Pro Series

Kaysun Prodigy Pro Series User Manual - German - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info