467831
8
Zoom out
Zoom in
Previous page
1/20
Next page
8
All brick flues or any flue previously used with
solid fuel or gas appliances must be left with the
appropriate debris collection volume below the flue
spigot of the stove of 12 litres minimum, and depth of
250 mm minimum below the spigot as shown in fig. 9.
Block, clay, cement or steel lined (connected to the top
of the appliance opening) flues either new or previ-
ously used with GAS appliances may have the smaller
debris collection volume of 2 litres minimum and
depth of 75 mm minimum below the flue spigot.
Make sure that there will be at least 50 mm clear-
ance between the end of the spigot and knee of the
fireback for flue gases. Also make sure that the spigot
will pass through the closure plate by a minimum of
15 mm. It can be extended by up to 150 mm (6”) to
ensure this requirement is met using a purpose-made
extension or suitable piece of flue pipe. Cut a closure
plate from sheet aluminum or steel to just cover the
appliance opening to be used. It is also possible to use
other fireproof materials providing they are properly
supported and sealed and can be removed annually
for inspection and clearing of the flue. Cut a spigot
hole as shown in the fig. 9. Fix the closure plate to the
wall or appliance and seal it correctly to the wall. The
plate must be sealed correctly to the wall using adhe-
sive sealant, screws and/or tape able to withstand at
least 3 degrees C. The appliance will not work correctly
and may cut out repeatedly if the sealing of the appli-
ance and flue is not correct.
Remember, if the closure plate extends beyond
the sides or top of the stove, a non-combustible
decorative panel can be fitted to cover the area. The
closure plate can then be fitted to this. Marble in-fill
panels are a common example. Install the appliance
and connect to the gas supply and carry out a smoke
test on the flue as described in the relevant section of
this manual.
Assembly Prior To Installation
The product is delivered in 1 package. In the firebox you
will find the propane fuel conversion kit, four decora-
tive pipe brackets, and a log set that includes a bag of
textured embers.
1. Remove the Top Plate of the stove by simply lifting it
straight off of the stove body.
2. To open the firebox, disengage the two Glass Frame
Latches located on top of the firebox. Pull each handle
forward to clear the latch from the notch in the frame.
See fig. 10.
3. Remove the parts wrapped in packaging. Use gloves
to handle the ceramic logs, as they can cause skin ir-
ritation.
4. Familiarize yourself with the installation require-
ments specified in this manual, before beginning the
installation. If the product is going to be used with
Propane G31 rather than G20 natural gas, it should be
converted now. See the instructions supplied with the
conversion kit.
Glass Frame
Latch
Figure 10. Pull spring latch to disengage from glass frame.
Minimum Clearances from Combustible
Material to the Vent System
All pipe components must be installed according to ap-
proval and the instructions of the manufacturer. Adhere
to the instructions of the manufacturer as regards clear-
ance from to the vent system to combustible material.
When moving the chimney the clearance from
combustible material to the upper side of horizontal
pipe must be minimum 100 mm. The clearance from the
bottom of the vent pipe to combustible material must be
minimum 75 mm.
Ventilation
For UK installation, please comply with BS 5440-2 which
states that for every 1 kW above 7 kW gas input, there
must be 5 cm
2
of additional purpose provided ventilation.
For example: if the input is 8.7 kW (see stove data
badge) this requires 1.7 kW x 5 cm
2
= 8.5 cm
2
of perma-
nent ventilation.
For other countries, please consult local regulations
and standards.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jotul GF 400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jotul GF 400 in the language / languages: English as an attachment in your email.

The manual is 1,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info