467831
7
Zoom out
Zoom in
Previous page
1/20
Next page
7
Figure 7. Clearance to a combustible shelf.
Flue System Installation
Flue outlet (spigot) dimensions:
Internally = 128 mm
Externally = approx. 131 mm
When installing the vent, it is important to adhere to
national and local regulations that apply. Only one appli-
ance may be connected to the vent system.
The vent system must terminate above the roof.
The vent system and the flue pipe components must
be fastened to the stove with screws.
Minimum height of the chimney is approx. 2,15 m (7’)
and maximum height should not be more than approx.
10,7 m (35’). (When installation is at or above a height of
approx. 610 m (2000’), the chimney’s height must be at
least approx. 3,7 m (12’.) measured from the flue outlet. If
the chimney has to move through a horizontal distance,
make sure to use 45º or 90 º bends.
Max. number of 45º bends = 4
Max. number of 90º bends = 3
It is permitted to move the chimney a total of approx.
1,2 m (4’) horizontally.
An exhaust hood (terminal, cowl or rain cap) must be
mounted at the chimney’s termination point . After fit-
ting of the vent system and installation of the appliance,
carry out a smoke test on the flue as described in the
relevant section. If the appliance shuts off in operation
for no apparent reason (especially during windy or stormy
conditions) and will not relight, it is possible that the flue
system safety switch has operated. Allow the appliance
to cool down and relight. Any obstruction to the flow of
exhaust gases up the flue can cause this switch to operate
thereby making the situation safe. If the appliance cuts
out repeatedly, do not continue to use the appliance and
seek flue checking and service from qualified personnel
before re-using the appliance.
Closure Plate Installation
It is permissible to install this appliance using a closure
plate installation similar to traditional outset gas fires.
See diagrams (1 E-F) on page 28. The British Standards de-
tailing this type of installation are BS5871 pt1 and BS5440
pt 1. The appliance and flue must be sound and if used
with solid fuel or oil appliances it must be swept prior to
installation. There must be no other openings other than
the exit from the top of the flue and the opening into
which the appliance is being installed. All cracks, holes,
underfloor air vents etc must be removed and sealed fully
before installation continues. A proprietary metal flue box
complying with BS715 is a suitable appliance opening.
Figure 8. Vent height requirements.
Figure 9. Closure plate and flue requirements.

















Closure Plate
600 mm
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jotul GF 400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jotul GF 400 in the language / languages: English as an attachment in your email.

The manual is 1,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info