Installer Information
The Flue must be checked for soundness and swept prior
to installation it should only be used if clean and in good
order.
Before installation, check that the local distribution
conditions, nature of the gas and pressure, and the ad-
justment of the appliance are compatible.
Assembly, installation, maintenance and gas conver-
sion (if required) must be performed by a qualified person
in accordance with the instructions for assembly, Installa-
tion and use enclosed with the product. The installation
may only be operated after it has been inspected by a
qualified person and a certificate of completion has been
issued.
The Installation should be carried out in accordance
with the Building Regulations which include the follow-
ing standards for installation and maintenance of flues,
ventilation and installation of Gas Fires. For UK BS5440:1,
BS5440:2, BS5871 for Republic of Ireland IS813, ICP3, IS327
The appliance is designed as a heating device and
all components will become hot (excluding control knob,
control cover and control switch) care should be taken not
to touch unit when it is in operation.
This appliance incorporates a spillage monitoring
device (TTB) this device will shutdown the appliance in
the event of interruption to the evacuation of combustion
products. I.e. Flue Blockage.
WARNING:
The TTB shall not be adjusted by the installer.
The TTB shall not be put out of operation by
the installer.
When the TTB is exchanged; only original
manufacturer’s parts shall be used.
Installation Guide for Qualified
Personnel
Important: The appliance is factory pre-set for Natural
Gas G20. If Propane G31 is to be used, the appliance
must be converted with a conversion kit. The instruc-
tions are enclosed with the conversion kit. The kit is
only to be installed by qualified personnel.
Fixing
The GF 400 CF is designed as a freestanding appliance
and as such does not require additional fixing.
Requirements for Floor Plate
The appliance may stand on a wooden floor. A floor
plate of non-combustible material is required if the
appliance is to be placed on carpet, vinyl, linoleum or
other combustible material. Minimum dimensions of
the floor plate: 686 x 356 mm as in fig. 4.
Firewall Requirements
The appliance may be placed directly against a wall made
of combustible material with the clearances specified in
fig. 5. Make sure there is adequate space for the vent sys-
tem behind the appliance and for the full height/length
of the pipe.
Position of Appliance
Minimum clearances are as follows:
Clearance from wall to rear of appliance, (see figs. 5).
Clearance from wall to side of appliance (see fig.5).
Minimum clearance from top of appliance to register
plate, (see fig. 6).
Minimum clearance from top of appliance to combustible
shelf, (see fig. 7).
Figure 6. Clearance for glass panel removal.
Figure 5. Parallel Installation Clearances.
Figure 4. Minimum Hearth Protection.
356 mm
686 mm
100 mm
To Rear
Combustible or
Noncomubustible
Wall
100 mm
100 mm



6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jotul GF 400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jotul GF 400 in the language / languages: English as an attachment in your email.

The manual is 1,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info