atmosphere. The test apparatus must have correct nominal values. Replace components
only with parts specified by the manufacturer. Other parts can cause the refrigerant to
ignite in the atmosphere from a leak.
4. WIRING
Verify that the wiring is not subject to wear, corrosion, excessive pressure, vibration,
sharp edges, or other adverse environmental effects. The control must also take into
account the effects of aging or continuous vibrations from sources such as compressors
or fans.
5. DETECTION OF FLAMMABLE REFRIGERANTS
Under no circumstances should potential ignition sources be used in searching for or
detecting refrigerant leaks. Do not use a halide torch (or any other detector that uses
a naked flame).
6. LEAK DETECTION METHODS
The following leak detection methods are considered acceptable for systems containing
flammable refrigerants. Electronic leak detectors must be used to detect flammable
refrigerants, but sensitivity may not be adequate or may require recalibration. (The
detection equipment must be calibrated in an area free of refrigerant.) Make sure
that the detector is not a potential source of ignition and is suitable for the refrigerant
used. The leak detection equipment must be set to a percentage of the LFL of the
refrigerant and calibrated to the refrigerant used and the appropriate percentage
of gas confirmed (25% maximum). Fluid leak detectors are suitable for use with most
refrigerant fluids but the use of detergents that contain bleach must be avoided as
they can react with the refrigerant and corrode the copper piping network. If a leak
is suspected, all naked flames must be removed / extinguished. If a refrigerant leak
that requires brazing is detected, all refrigerant must be recovered from the system or
isolated (via shut-off valves) in a part of the system away from the leak. Oxygen Free
Nitrogen (OFN) must therefore be purged through the system both before and during
the brazing process.
GB
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Innoliving INN-521 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Innoliving INN-521 in the language / languages: English, Italian as an attachment in your email.

The manual is 3.42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info