Chapter 3. Calibration
To comply with precision requirements, you should have your LanTEK III and FiberTEK III Cable
Tester calibrated on an annual basis. Before sending the tester for calibration or maintenance, please
contact the local Technical Customer Service of IDEAL INDUSTRIES at www.idealnetworks.net
3.1 Field Calibration
During calibration, FiberTEK™ III calculates a reference level for the loss measurement. Calibration
accuracy depends on warm-up period of measuring adapter and quality of the test cords.
NOTE
The launch and tail cords must correspond to the type of fiber to be tested (e.g. 50-m launch fibers for
testing of 50-m cable).
All connections on launch, tail and reference cords must be in compliance with the requirements of
ISO/IEC 14763-3 concerning length as well as insertion loss.
To ensure the specified measuring accuracy, a sufficient warm up period must be allowed for the
measuring adapter.
The temperature of LanTEK
®
III Cable Tester and measuring adapter should correspond to the ambient
temperature.
To prevent condensation on optics, do not remove dust covers on measuring adapters before performing
cable test.
Close optical input/output again immediately with dust covers after removal of launch fibers.
The field calibration values are saved in the Display handset (DH). The loss of the launch fibers and
couplers used during calibration are deducted from the loss results during the cable test.
Before testing of fibers a calibration should be performed if:
the launch cords have been subject to change or strong movement;
the fiber type has been changed;
the measuring adapters have been changed;
3.2 Performing Field Calibration
1. Connect the reference patch cables between the Display handset (DH) and Remote handset
(RH) (Normal mode) or looped on the Display handset (Loop mode).
2. Once connected, do not disconnect the Tx reference patch cable until testing on the target
cables is complete.
3. Use Arrow Keys to navigate on ready screen to "Calibration" and press Enter.
4. Select required calibration method
NOTE
The Field Calibration should be performed using the same arrangement of jumpers as will be used in the
tests.
1. Use Arrow Keys to navigate on ready screen to " Field Calibration" display and confirm with
Enter.
2. Select the required method:
In the 1-Jumper test method, the cable under test must be plugged directly into
the Rx Port of the FiberTEK™ III. Field Calibration uses a single jumper (Launch
Cord) for each direction.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ideal Networks FiberTEK III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ideal Networks FiberTEK III in the language / languages: English as an attachment in your email.

The manual is 0,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info