670434
76
Zoom out
Zoom in
Previous page
1/96
Next page
11
SET MODE
11-9
Display
LCD Backlight (Default: 50%)
Sets the LCD backlight brightness.
Range: 0 (dark) ~ 100% (bright)
LED Bright (Default: 80%)
Sets the LED brightness.
Range: 0 (dark) ~ 100% (bright)
Display Type (Default: A)
Sets the display background type to A or B.
• A: Display background color is black.
• B: Display background color is blue.
Meter Peak Hold (Default: ON)
Turns the Meter Peak Hold function ON or OFF.
OFF: Does not hold the peak level.
ON: Holds the peak level on the signal meter
display for 0.5 seconds.
Memory Name (Default: ON)
Turns the Memory name display in the Memory mode
ON or OFF.
OFF: Memory name is not displayed, even if entered.
• ON: The entered Memory name is displayed
above the frequency display.
Group Name Popup (Default: ON)
Select whether or not to display the group name when
you change the memory channel group.
OFF: The group name is not displayed.
• ON: The group name is displayed.
MN-Q Popup (MN OFF→ON) (Default: ON)
Selects whether or not to display the Manual Notch
lter width when you select the Manual Notch.
OFF: The Manual Notch lter width is not displayed.
ON: The Manual Notch lter width is displayed.
BW Popup (PBT) (Default: ON)
Selects whether or not to display the digital TWIN PBT
shift value while rotating
TWIN PBT
CLR
.
OFF: The the PBT and center shift value are not
displayed.
ON:
The the PBT and center shift value are displayed.
BW Popup (FIL) (Default: ON)
Selects whether or not to display the digital IF lter
width and shift value when you change the IF lter.
OFF:
The IF lter width and shift value are not displayed.
ON:
The IF lter width and shift value are displayed.
MENU
» SET > Display
RX Popup (Default: Normal)
Selects whether or not to display the information included
in the received digital signal such as call sign, caller’s ID,
code and so on, when you receive a digital signal.
OFF: The information is not displayed.
• Normal: The information is displayed for
approximately 3 seconds.
RX Hold: The information is displayed until an
operation is performed.
Hold:
The information is displayed and remains,
even an operation is performed.
P25 RX ID Display (Default: Dec)
Selects the P25 Talk-group ID display type.
Dec: In Decimal.
Hex:
In Hexadecimal.
Screen Saver (Default: 60min)
Sets the Screen Saver function.
This function activates and automatically turns OFF
the screen* when no operation is performed for the
preset period of time.
OFF: Turns OFF the function.
15min: Activates after 15 minutes with no operation.
30min: Activates after 30 minutes with no operation.
60min: Activates after 60 minutes with no operation.
* indicator blinks.
Opening Message (Default: ON)
Selects whether or not to display the opening message
(including the opening comment) at power ON.
• OFF: Opening message is not displayed.
• ON: Opening message is displayed.
Opening Comment
Enter the opening comment displayed with the
opening message at power ON.
LPush to change the keyboard type.
LRefer to page 1-7 for the character entering.
Display Language (Default: English)
Sets the display language.
• English: Displays in English.
• Japanese: Displays in Japanese.
L This item is not displayed when “English” is selected in
the “System Language” item.
System Language (Default: English)
Sets the system language.
• English: Displays in English.
• Japanese: Displays in Japanese.
L
If you set the language to English, all Japanese characters
(such as memory name) you entered are garbled. But the
display returns to normal when you change to Japanese again.
76


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-R8600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-R8600 in the language / languages: English as an attachment in your email.

The manual is 22,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info