SET MODE
11-7
Connectors (Continued)
CI-V > CI-V USB (Rear) Port
(Default: Unlink from [REMOTE])
Selects the internal connection type between the [USB]
port on the rear panel and the [REMOTE] CI-V port.
• Link to [REMOTE]:
The [USB] port on the rear panel and the
[REMOTE] CI-V port are internally connected.
• Unlink from [REMOTE]:
The [USB] port on the rear panel and [REMOTE]
CI-V port are not internally connected.
Each port functions independently.
(duplex communication can be made.)
CI-V > CI-V USB (Rear) Baud Rate (Default: Auto)
Selects the CI-V data transfer rate (bps) for [USB] on
the rear panel.
Options:
4800, 9600, 19200, 38400, 57600, 115200 or Auto
L When “Auto” is selected, the baud rate is automatically set
according to the data rate of the connected controller.
L This setting is valid only when the “CI-V USB Port” item is
set to “Unlink from [REMOTE].”
CI-V >
CI-V USB (Rear) Echo Back (Default: OFF)
Turns the Data Echo Back function ON or OFF, when
remotely controlling through the [USB] CI-V port.
OFF: Turns OFF the function.
• ON: Turns ON the function.
L This setting is .valid only when the “CI-V USB Port” item is
set to “Unlink from [REMOTE].”
External Meter Output (Default: Signal)
Selects the signal output from [METER].
• Signal: Signal strength.
Signal+SQL: Signal strength and squelch level.
External Meter Level (Default: 50%)
Sets the voltage level output from [METER].
Range: 0 ~ 100%
L 8 V DC is output at full scale (50%). (into a 10 kΩ load)
REF IN/OUT (Default: OFF)
Selects the receiver’s reference frequency signal source.
• IN: Uses an external reference signal.
NOTE: SELECT “OFF” or “OUT” if you are
not use a reliable external signal source.
When the input signal source level is too low,
or the frequency precision is not high, the fre-
quency readout blinks and the receiver does
not function correctly.
• OFF: Does not input/output the reference signal.
• OUT: Outputs the internal reference signal.
Network
DHCP (Valid after Restart) (Default: ON)
Turns the DHCP function ON or OFF.
• OFF: Uses the static IP address.
• ON: Uses the DHCP function.
If a DHCP server is in your network environ-
ment, the IP address is automatically obtained.
LThis setting takes effect after restart.
IP Address (Valid after Restart)
(Default: 192.168. 0. 10)
Sets the static IP address.
L This setting is valid when “OFF” is selected the [DHCP
(Valid after Restart)] item.
LThis setting takes effect after restart.
Subnet Mask (Valid after Restart)
(Default: 255.255.255.0 (24bit))
Sets the subnet mask to connect to your PC or LAN
(Local Area Network), through the Ethernet. Rotate
to set.
Range: 128.0.0.0 (1 bit) ~ 255.255.255.252 (30 bit)
LThis setting takes effect after restart.
Default Gateway (Valid after Restart)
(Default: . . . )
When you remotely control the IC-R8600 using the
optional RS-R8600 (future product), a default gateway
setting is required.
L This setting is valid when “OFF” is selected the [DHCP
(Valid after Restart)] item.
LThis setting takes effect after restart.
Primary DNS Server (Valid after Restart)
(Default: . . . )
If there are two DNS server addresses, enter the pri-
mary DNS server address.
LThis setting takes effect after restart.
2nd DNS Server (Valid after Restart)
(Default: . . . )
If there are two DNS server addresses, enter the sec-
ondary DNS server address.
LThis setting takes effect after restart.
MENU
» SET > Network
74


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-R8600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-R8600 in the language / languages: English as an attachment in your email.

The manual is 22,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info