670164
72
Zoom out
Zoom in
Previous page
1/104
Next page
9
67
ANTENNA TUNER OPERATION
Optional AT-180 automatic antenna tuner operation
The AT-180 automatic antenna tuner matches the
IC-7200 to the connected antenna automatically.
Once the tuner matches an antenna, the variable
capacitor settings are memorized as a preset point
for each frequency range (100 kHz steps). Therefore,
when you change the frequency range, the variable
capacitors are automatically preset to the memorized
point.
NOTE:
The AT-180 can match both HF and 50 MHz
bands. However, operation is different for the HF
and 50 MHz bands.
When connecting the AT-180, the IC-7200’s out-
put power must be more than 10 W. Otherwise,
the AT-180 may not be tuned correctly. (AT-180’s
minimum operating input power is 8 W.)
CAUTION: NEVER transmit with the tuner ON
when no antenna is connected. This will damage
both the transceiver and antenna tuner.
MODE
TUNER
TS
FILTER
SPCH
V/M
A/B
SPLIT
M-CL
SCAN
SET
ATT
P
.
AMP
COMP
VOX
MNF
RIT
1
2
3
4
5 6
7
8
0
50
28
1814
10
21
24
=
7
3.5
1.8
F-INP
M-CH/RIT
ENT
BAND
GENE
9
.
AGC
MW
ANF
METER
NR
NB
TUNER
D Tuner operation
• For the HF band:
Push
TUNER
to turn the tuner ON. The antenna is
tuned automatically during transmission when the
antenna SWR is higher than 1.5:1.
When the tuner is ON, indication appears.
• For the 50 MHz band:
Push and hold
TUNER
for 1 sec. to tune the antenna.
If indicator blinks slowly while transmitting,
push and hold
TUNER
for 1 sec. again to re-tune the
antenna.
D Manual tuning
During SSB operation on HF bands at low voice lev-
els, the AT-180 may not be tuned correctly. In such
cases, manual tuning is helpful.
Push and hold
TUNER
for 1 sec. to start manual tun-
ing.
When CW mode is selected, a side tone is emitted, and
indicator blinks; then, the previous mode is se-
lected.
If the tuner cannot reduce the SWR to less than
1.5:1 after 20 sec. of tuning, indicator disap-
pears. In this case, check the following:
• the antenna connection and feedline
the antenna SWR (p. 30; meter function, p. 60;
Measuring SWR)
Through inhibit (HF bands only)
The AT-180 has a through inhibit condition. When
selecting this condition, the tuner can be used at
poor SWR’s. In this case, automatic tuning in the
HF bands activates only when exceeding SWR 3:1.
Therefore, manual tuning is necessary each time you
change the frequency. Although termed “through in-
hibit, the tuner will be set to the “through” configura-
tion if the SWR is higher than 3:1 after tuning.
CONVENIENT
Tuner sensitive condition (HF bands only)
If you require critical tuning at any time during trans-
mission, select the tuner sensitive condition.
See p. 68 for selection.
• Automatic tuner start (HF bands only)
If you want to turn OFF the tuner under conditions
of VSWR 1.5:1 or less, use “automatic tuner on” and
turn the tuner OFF. See p. 76 for the automatic tuner
function.
• PTT tune function (p. 76)
The AT-180 is tuned when [PTT] is pushed after the
frequency is changed (more than 1%) if the AT-180 is
turned ON. This function removes the “push and hold
TUNER
operation and activates first transmission
on the new frequency.
This function is turned ON in the set mode.
72


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-7200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-7200 in the language / languages: English as an attachment in your email.

The manual is 10,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info