3. The sensor connections are made in dedicated pairs:
one wire to the sensor number + terminal, the other
wire from the sensor to its terminal. Do not twist
common wires together from different sensors and
connect them to the same terminal.
4. Loosen the screw for the first sensor terminal
(SEN1), and connect either of its wires to the +
terminal and tighten.
5. Connect the other wire from that sensor to the SEN1
terminal and tighten.
6. To connect the wireless Rain Clik (WRC) or wireless
Rain-Freeze Clik receiver, consult the instructions
supplied with the WRC for mounting and addressing.
7. Connect either of the receivers Yellow power wires
to the 24 VAC terminal on the Master Module (the
24 VAC terminal has a 400 mA maximum capacity
and is adequate for Clik receivers).
8. Connect the other Yellow receiver wire to any of the
COM terminals.
9. Complete the wireless Clik installation according to
the WRC instructions.
All additional programming is performed at the facepack
and is described in the Set Sensor Operation section of
Programming and Operations.
ConneCTInG The hunTer floW sensor .....................................
The HFS is the primary flow meter for which ACC flow
functions have been designed. Additional types of flow
sensor connections may also be possible. Consult flow
sensor manual for wiring and calibration information.
1. To connect a HFS, route the pair of 18 AWG (1 mm)
wires from the sensor into the cabinet through one
of the low voltage conduit openings in the bottom of
the enclosure.
2. Locate the Flow red and black coded terminals
near the left side of the Master Module. Connect the
red wire from the HFS to the red terminal, and the
black wire from the HFS to the black terminal.
3. Reversing the red and black connections will
probably not damage the units, but will not allow the
ACC to read flow.
4. Flow setup, learning, and configuration is described
in the Set Flow Monitoring section of Programming
and Operations.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hunter ACC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hunter ACC in the language / languages: English as an attachment in your email.

The manual is 7,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hunter ACC

Hunter ACC User Manual - German - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info