66 04.2007 TR10A041-C RE
Operator lighting by radio signal, external push-button
not active
5 minutes
10 minutes
15 minutes
Radio function of the 2nd channel
Operator lighting
Partial opening
Press the PRG button to return to normal operation
(menu 0).
6.3 MENU 0 – normal operation
In normal mode, the garage door operator operates
with impulse sequence control, activated via an external
push-button or a learned radio code:
1st impulse: door travels towards the end-of-travel
position
2nd impulse: door stops
3rd impulse: door travels in the other direction
4th impulse: door stops
5th impulse: door travels towards the end-of-travel
position selected with the first impulse
etc.
6.3.1 Behaviour of the garage door operator after
2-3 fast-opening cycles in succession
Note
The motor of the garage door operator features thermal
overload protection.
If within 2 minutes 2-3 fast-opening cycles take place in
succession, this safeguard reduces the speed, i.e. travel in
both the OPEN and CLOSE directions proceeds at the
same speed. After a rest period of a further two minutes,
the next opening cycle is performed at fast speed again.
7 SPECIAL MENUS
7.1 Selecting the special menus
To access the special menus (menu 3 - menu A), simul-
taneously press the OPEN button () and the CLOSE
button () in menu 2. The service menus can be selected
via the PRG button.
7.2 General information on the special menus
(Menu 3 – menu A)
Upon selection, the menu number remains displayed for
a short period. Subsequently, the first active menu para-
meter is shown flashing slowly. Press the OPEN button
() or the CLOSE button () to page through the menu.
The active parameter or parameters are indicated by a
glowing decimal point.
To change a parameter, press and hold the PRG button
until the display flashes rapidly. Press the OPEN button
() and the CLOSE button () to page through the menu.
The active parameter is indicated by a glowing decimal
point. To activate a parameter, press the PRG button until
the decimal point lights up. If the PRG button is released
prematurely, this calls up the next menu. If no button is
pressed and the operator has completed the learning
process, the control system automatically returns to nor-
mal operation (menu 0).
7.2.1 7-segment display when changing from the
customer menu to the special menus
Note
When changing to the special menus, depending on the
current setting in menu 2, a number between "0" and "6"
flashes in the 7-segment display.
7.2.2 7-segment display after selecting a special menu
Note
After selecting a special menu, a number between 0…9
can flash in the 7-segment display, depending on the menu.
This number indicates the (first) active parameter
7.3 MENU 3 – automatic timed closing (see fig. 24 )
Note
Automatic timed closing can only be activated when at
least one safety device is active (menu 4).
Display Automatic timed closing
not activated
after 10 seconds
after 20 seconds
after 30 seconds
after 45 seconds
after 60 seconds
after 90 seconds
after 120 seconds
after 150 seconds
after 180 seconds
Note
If the operator receives an impulse during automatic timed
closing (menu 3, parameter greater than 0), then the door
stops and opens again.
Press the PRG button to return to normal operation
(menu 0).
ENGLISH
37


Need help? Post your question in this forum.

Forumrules
1

Forum

hormann-supramatic-2

Reset search

  • Avrei necessità di riprogrammare il mio SupraMatic P 2 nennlast 225 N. Submitted on 23-3-2023 at 18:59

    Reply Report abuse
  • Tengo un supramatic E2 y quiero conectar una apertura por WiFi, quisiera saber a que conectores, va el modulo wifi Submitted on 28-9-2022 at 18:37

    Reply Report abuse
  • With my previous house I was able to connect additional mains (LED) internal garage lighting that operated in unison with the lighting on the Supermatic. Am I able to do this with the new Supermatic, and what connections do I need to use. Thanks VM Submitted on 16-2-2022 at 16:29

    Reply Report abuse
  • Hoe kan ik de garagepoort "ontkoppelen" van de ketting van de motorisatie om bij stroomuitval manueel te kunnen bedienen? Submitted on 10-5-2021 at 00:39

    Reply Report abuse
  • Good morning,

    We have a Hormann Supramatic E2. Very happy with it. This morning however, it closes fine but only opens about 40 cm. This from main button as remote control. Both have the same result. It will close without problem. We have unplugged it and replugged after a few minutes. The track appears to be clear and clean. There is a 5 in red appearing on main unit but I don't know if this is normal to be honest. Advice will be very welcome.
    Mariet Procter Submitted on 7-1-2021 at 11:20

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hormann Supramatic 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hormann Supramatic 2 in the language / languages: English as an attachment in your email.

The manual is 7,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hormann Supramatic 2

Hormann Supramatic 2 Usermanual and installation guide - German - 56 pages

Hormann Supramatic 2 User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info