Installation & Programming Guide — 21
Zone Doubling
Zone doubling can be achieved on the Windsor 300. The alarm input is used for one alarm
and the tamper input is used as a second alarm input. To allow zone doubling to operate,
the panel must be programmed. From engineer mode enter 060
Code Function Options
060 Zone Doubling 0 - Off : 1 - On
The doubling when selected applies to zones 1 - 8 . Zone doubling does not operate on
keypad zones. The normal zone types as defined in Option Table 1 all apply to the zone
doubled programming.
Zone doubling EOL
Zone doubling can be used on
the End of LIne variant of
Windsor 300. For EOL versions
the first alarm requires the 2k7
resistor to be used and the zone
doubled or secondary alarm
required the 8k2 resistor to be
used. The detector +12V and 0V
are provided from the control
panel auxiliary supply and the
detector tampers are part of a
global tamper loop using the
system tamper on the main PCB
or the power supply PCB.
The zones 1 - 8 on the main PCB will use the 2k7 resistors and will be indicated as zones
1 - 8. The tamper for zones 1 - 8 will use the 8k2 resistors and will be indicated as zones
9 - 16 for the panel.
AUX
ALARM
TAMPER
AUX
ALARM
TAMPER
TAMPER
TAMPER
+12V
A
T
0V
+12V
A
T
0V
R
2k7
0V
+12V
ALARM (1)
GLOBAL TAMPER
LOOP FOR
DETECTOR
TAMPERS
8k2
0V
+12V
ALARM (1 +16)
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Guardall WINDSOR SERIES 300i at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Guardall WINDSOR SERIES 300i in the language / languages: English as an attachment in your email.

The manual is 0,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info