22 — Installation & Programming Guide
Shock Sensor Input
The Windsor 300 control panel can have shock sensors connected directly to the zone
inputs and do not require an analyser PCB. The shock sensor input must have a
debounce period programmed to allow the zone to operate. The debounce period is the
time the shock sensor remains open or active. This time is used to program the actual
sensitivity of the unit i.e. the shorter the time period, the more sensitive the response and
the longer the time the less sensitive the unit.
Shock sensor processing is only available on zones 1 and 2 on the main PCB and on
zones 09 - 32 on the external concentrator zones. To program shock sensor inputs, enter
engineer mode and proceed as follows :
Code Function Options
101 Zone 1 programming 6 - 300 ms
102 Zone 2 programming 6 - 300 ms
109 Zone 9 programming 6 - 300 ms
to to
132 Zone 32 programming 6 - 300 ms
The time for the option is entered directly and once entered, the option must be confirmed
prior to moving onto the next zone. Setting up the shock sensor should be completed
using 'walk test' and each zone should be set up to obtain the correct level of sensitivity by
altering the time option until the correct level is obtained.
If shock sensors are connected to zones 1 and 2 and zone doubling activated, the time
programmed for zones 1 and 2 is applied for the zone doubled inputs.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Guardall WINDSOR SERIES 300i at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Guardall WINDSOR SERIES 300i in the language / languages: English as an attachment in your email.

The manual is 0,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info