6.1 Transient Overvoltages
The multimeter is protected against transient voltages of up to 4 kV with front
and half times of up to 1.2 and 50 s respectively. Due to the fact that powerful
overvoltages must be reckoned with during measurement, for example in power
systems, at transformers or motors, we recommend the use of our KS30 mea-
suring adapter in such cases. It offers protection against transient overvoltages
of up to 6 kV with front and half times of up to 10 and 1000 s respectively.
Continuous load capacity is equal to 1200 V
eff
. Additional measuring error
due to use of the KS30 measuring adapter amounts to approximately –2%.
6.2 Measuring Voltages of Greater than 300 V
Voltages of greater than 300 V can be measured with a high-voltage measuring
probe, for example the HV3
1)
of the HV30
2)
from GMC-I Messtechnik GmbH.
The bonding terminal must be grounded in this case. Observe all applicable
safety precautions!
1)
HV3: 3 kV
2)
HV30: 30 kV for (DC) voltage only
6.3 Low-Voltage Measurement
The instrument is equipped with a special 30 mV measuring range for measuring
voltage drop at fuses which is distinguished by high resolution (10 V) with a low
input resistance of 50 k.
Set the rotary switch to “Temp RTD”.
Select “V DC” measurement with probe by repeatedly pressing the FUNC
key until “mV DC” appears at the display.
Connect
the probe to the ” and “V” sockets.
7 Current Measurement
First disconnect supply power from the measuring circuit or the power
consumer and discharge all capacitors, if any are present.
Depending upon the type of current, set the rotary switch toA ” or “A .
The symbol for the selected current type, (DC) or ~ (AC), appears at the LCD.
Connect the measuring instrument securely to the power consumer in se-
ries as shown in the diagram (without transition resistor).
black
black
red
x1000
x100
Measuring voltages of greater than 300 V
with the HV3 high-voltage probe
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAport 40S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAport 40S in the language / languages: English as an attachment in your email.

The manual is 0,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info